Literature DB >> 22949487

Two zotarolimus-eluting stent generations: a meta-analysis of 12 randomised trials versus other limus-eluting stents and an adjusted indirect comparison.

Salvatore Cassese1, Gjin Ndrepepa, Lamin A King, Tomohisa Tada, Massimiliano Fusaro, Adnan Kastrati.   

Abstract

OBJECTIVE: To evaluate efficacy and safety of two zotarolimus-eluting stent generations versus other limus-eluting stents (LES), and to compare Resolute zotarolimus-eluting stents (R-ZES) with Endeavor zotarolimus-eluting stents (E-ZES).
BACKGROUND: The performance of zotarolimus-eluting stents versus other LES, and the possible improvements of R-ZES versus E-ZES still remain to be defined.
METHODS: We undertook a meta-analysis of trials in which patients were randomly assigned to percutaneous coronary interventions (PCI) with R-ZES versus LES, or with E-ZES versus LES, as well as an indirect comparison of R-ZES versus E-ZES, with LES as common comparator. The primary efficacy endpoint was ischaemia-driven target vessel revascularisation (ID-TVR); the primary safety endpoints were myocardial infarction (MI), cardiac death and cumulative definite/probable stent thrombosis (ST).
RESULTS: Overall, 13'709 patients were assigned to PCI with R-ZES versus LES (n=7185) or with E-ZES versus LES (n=6524). The risk of ID-TVR (OR (95% CI)=1.06 (0.90 to 1.25), p=0.47), MI (1.00 (0.81 to 1.25), p=0.97), cardiac death (0.99 (0.69 to 1.42), p=0.96) and ST (1.18 (0.68 to 2.03), p=0.56) did not differ between R-ZES and LES. Patients receiving E-ZES were more likely to undergo ID-TVR as compared with those receiving LES (1.95 (1.40 to 2.73), p<0.0001). The risk of MI (0.91 (0.54 to 1.54), p=0.73), cardiac death (1.02 (0.54 to 1.91), p=0.96) and ST (1.10 (0.50 to 2.44), p=0.81) was similar between E-ZES and LES. At indirect comparison, PCI with R-ZES versus E-ZES reduced the risk of ID-TVR (0.54 (0.37 to 0.78), p=0.001), without increasing MI (1.09 (0.62 to 1.93), p=0.74), cardiac death (0.97 (0.46 to 2.00), p=0.93) and ST (1.07 (0.40 to 2.80), p=0.88).
CONCLUSIONS: The antirestenotic efficacy of Resolute zotarolimus-eluting stents is superior to Endeavor zotarolimus-eluting stents and similar to other limus-eluting stents. Endeavor zotarolimus-eluting stents increase the risk of reinterventions as compared with other limus-eluting stents. First and second-generation zotarolimus-eluting stents have similar thrombogenicity compared with other limus-eluting stents.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22949487     DOI: 10.1136/heartjnl-2012-302519

Source DB:  PubMed          Journal:  Heart        ISSN: 1355-6037            Impact factor:   5.994


  5 in total

1.  Clinical outcome after percutaneous treatment of de novo coronary bifurcation lesions using first or second generation of drug-eluting stents.

Authors:  Miroslaw Ferenc; Heinz Joachim Buettner; Michael Gick; Thomas Comberg; Juergen Rothe; Firas Khoury; Christian Valina; Aurel Toma; Piotr Kuebler; Florian Riede; Franz-Josef Neumann
Journal:  Clin Res Cardiol       Date:  2015-09-02       Impact factor: 5.460

Review 2.  New concepts in the design of drug-eluting coronary stents.

Authors:  Scot Garg; Christos Bourantas; Patrick W Serruys
Journal:  Nat Rev Cardiol       Date:  2013-02-19       Impact factor: 32.419

3.  Learning from the Cardiologists and Developing Eluting Stents Targeting the Mtor Pathway for Pulmonary Application; A Future Concept for Tracheal Stenosis.

Authors:  Paul Zarogoulidis; Kaid Darwiche; Kosmas Tsakiridis; Helmut Teschler; Lonny Yarmus; Konstantinos Zarogoulidis; Lutz Freitag
Journal:  J Mol Genet Med       Date:  2013-08-26

4.  Comparison of 3-year clinical outcomes between Endeavor Resolute® and Resolute Integrity® zotarolimus-eluting stents in an Asian population.

Authors:  Yong Hoon Kim; Ae-Young Her; Seung-Woon Rha; Byoung Geol Choi; Se Yeon Choi; Jae Kyeong Byun; Yoonjee Park; Dong Oh Kang; Won Young Jang; Woohyeun Kim; Cheol Ung Choi; Hong Seog Seo
Journal:  Anatol J Cardiol       Date:  2020-04       Impact factor: 1.596

5.  Comparison of the Major Clinical Outcomes for the Use of Endeavor® and Resolute Integrity® Zotarolimus-Eluting Stents During a Three-Year Follow-up.

Authors:  Yong Hoon Kim; Ae-Young Her; Seung-Woon Rha; Byoung Geol Choi; Se Yeon Choi; Jae Kyeong Byun; Yoonjee Park; Dong Oh Kang; Won Young Jang; Woohyeun Kim; Cheol Ung Choi; Chang Gyu Park; Hong Seog Seo
Journal:  Glob Heart       Date:  2020-02-06
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.