Literature DB >> 22949255

Impact assessment of odours emitted by a wastewater treatment plant.

Sandra P Beghi1, Jane Méri Santos, Neyval Costa Reis, Leandro Melo de Sá, Elisa Valentim Goulart, Elza de Abreu Costa.   

Abstract

Complaints from the Domingos Martins population about sewage odours in the city made the district attorney order an impact assessment of the odours emitted by the city wastewater treatment plant (WWTP). This study comprised various techniques, models and population surveys. In 2007, an odour emission model proved that the main hydrogen sulphide emitter was the aeration tank of the WWTP (13.5 g h(-1)) and such emissions, according to CALPUFF model, should be perceived in the whole Domingos Martins city centre area. In this area, 58% of those interviewed were annoyed by the WWTP odours. However, in 2009, the odour monitoring panel recorded few odour occurrences. A second population survey showed that hereafter only 20% of those interviewed were annoyed by the WWTP emissions. Odour emission and dispersion models run with 2010 data proved a drastic reduction of the WWTP aeration tank emissions and consequently the city centre was not bothered by WWTP emissions anymore. The odour emission reduction was due to the modification of the WWTP aeration tank system. Despite the odour emission reduction, houses located southeast of the WWTP were still annoyed by sewage odours. However, in this part of the town, other sources of sewage odours have been found.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22949255     DOI: 10.2166/wst.2012.409

Source DB:  PubMed          Journal:  Water Sci Technol        ISSN: 0273-1223            Impact factor:   1.915


  3 in total

1.  Pragmatic evaluation of odour emissions from a rendering plant in southern Brazil.

Authors:  Magnun M Vieira; Waldir N Schirmer; Henrique de Melo Lisboa; Paulo Belli Filho; Jean-Michel Guillot
Journal:  Environ Sci Pollut Res Int       Date:  2016-09-17       Impact factor: 4.223

Review 2.  Gas chromatography analysis with olfactometric detection (GC-O) as a useful methodology for chemical characterization of odorous compounds.

Authors:  Magda Brattoli; Ezia Cisternino; Paolo Rosario Dambruoso; Gianluigi de Gennaro; Pasquale Giungato; Antonio Mazzone; Jolanda Palmisani; Maria Tutino
Journal:  Sensors (Basel)       Date:  2013-12-05       Impact factor: 3.576

3.  Materials Contamination and Indoor Air Pollution Caused by Tar Products and Fungicidal Impregnations: Intervention Research in 2014-2019.

Authors:  Mateusz Kozicki; Adam Niesłochowski
Journal:  Sensors (Basel)       Date:  2020-07-23       Impact factor: 3.576

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.