Literature DB >> 22948627

Radiologic and long-term clinical outcome from treatment of isolated medial orbital wall blowout fractures.

Daniel Saiepour1, Elias Messo, Anders J O Hedlund, Daniel J Nowinski.   

Abstract

Blowout fractures in the medial orbital wall may lead to enophthalmos, ocular dysmotility, and diplopia. Ten consecutive patients with unilateral, isolated fractures of the medial orbital wall were retrospectively studied. The radiologic accuracy of the medial orbital wall reconstructions and the long-term clinical outcomes were assessed. All cases were treated through a bicoronal approach and by use of porous polyethylene-titanium implants. The total fracture area and the orbital volume increase from the blowout were measured on computed tomographic scans. Next, we evaluated the reconstruction in the posterior part of the medial wall. This was done by calculating the ratio between the defect area and the implant area located behind the anterior ethmoidal canal. The patients were examined at least 1 year after the operation, and the rates of enophthalmos and diplopia were evaluated. The mean fracture defect area was 2.45 cm2 (range, 0.41-4.16 cm2), and the mean volume increase from the blowout fractures was 1.82 cm3 (range, 0.53-2.76 cm3). The orbital volume was accurately restored in all patients. However, the ratio of implant to defect area behind the anterior ethmoidal canal ranged from 0% to 100% (mean, 47.3%). None of the patients had enophthalmos or diplopia at the long-term follow-up. The results confirm that restoration of orbital volume is important to prevent postoperative enophthalmos in isolated medial orbital blowout fractures. Complete reconstruction of the most posterior part of the medial orbital wall seems to be of lesser importance.

Entities:  

Mesh:

Year:  2012        PMID: 22948627     DOI: 10.1097/SCS.0b013e31825e4e8e

Source DB:  PubMed          Journal:  J Craniofac Surg        ISSN: 1049-2275            Impact factor:   1.046


  4 in total

1.  3D printing for orbital volume anatomical measurement.

Authors:  Nolwenn Piot; Florent Barry; Matthias Schlund; Joël Ferri; Xavier Demondion; Romain Nicot
Journal:  Surg Radiol Anat       Date:  2022-07-02       Impact factor: 1.354

2.  Comparison of pre-bent titanium mesh versus polyethylene implants in patient specific orbital reconstructions.

Authors:  Marcin Kozakiewicz; Piotr Szymor
Journal:  Head Face Med       Date:  2013-10-29       Impact factor: 2.151

3.  The Correlation between the Orbital Volume Ratio and Enophthalmos in Unoperated Blowout Fractures.

Authors:  Su Hyun Choi; Dong Hee Kang; Ja Hea Gu
Journal:  Arch Plast Surg       Date:  2016-11-18

4.  Evaluation of orbital volume in unilateral orbital fracture using computed tomography.

Authors:  Gayathri R Nair; M S Senthil Kumar
Journal:  Natl J Maxillofac Surg       Date:  2022-07-15
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.