Literature DB >> 22948356

Investigation of BPF algorithm in cone-beam CT with 2D general trajectories.

Jing Zou1, Jianbao Gui, Junyan Rong, Zhanli Hu, Qiyang Zhang, Dan Xia.   

Abstract

A mathematical derivation was conducted to illustrate that exact 3D image reconstruction could be achieved for z-homogeneous phantoms from data acquired with 2D general trajectories using the back projection filtration (BPF) algorithm. The conclusion was verified by computer simulation and experimental result with a circular scanning trajectory. Furthermore, the effect of the non-uniform degree along z-axis of the phantoms on the accuracy of the 3D reconstruction by BPF algorithm was investigated by numerical simulation with a gradual-phantom and a disk-phantom. The preliminary result showed that the performance of BPF algorithm improved with the z-axis homogeneity of the scanned object.

Mesh:

Year:  2012        PMID: 22948356     DOI: 10.3233/XST-2012-0343

Source DB:  PubMed          Journal:  J Xray Sci Technol        ISSN: 0895-3996            Impact factor:   1.535


  1 in total

1.  Super-resolution CT Image Reconstruction Based on Dictionary Learning and Sparse Representation.

Authors:  Changhui Jiang; Qiyang Zhang; Rui Fan; Zhanli Hu
Journal:  Sci Rep       Date:  2018-06-11       Impact factor: 4.379

  1 in total