Literature DB >> 22946670

Shock anxiety among implantable cardioverter defibrillator recipients with recent tachyarrhythmia.

Ingvild M Morken1, Kjetil Isaksen, Bjørg Karlsen, Tone M Norekvål, Edvin Bru, Alf Inge Larsen.   

Abstract

BACKGROUND: Shock anxiety has been documented irrespective of shock exposure in implantable cardioverter defibrillator (ICD) recipients. The presence of tachyarrhythmia may lead to an anticipation of receiving a shock and thereby give rise to shock anxiety. The aims were to assess: (1) the level of shock anxiety in a sample of ICD recipients, (2) the relationship between such anxiety and shock exposure, and (3) the relationship between recent tachyarrhythmia and shock anxiety.
METHODS: ICD recipients (n = 167) completed the Florida Shock Anxiety Scale measure of shock anxiety. The recipients were divided into three groups: (1) Recipients with no documented tachyarrhythmia over the previous 12 months (n = 56), (2) recipients with documented tachyarrhythmia over the previous twelve months (n = 54), and (3) recipients with any history of shocks (n = 57).
RESULTS: Of the recipients, 44% experienced some form of shock anxiety, whereas 15% reported general shock anxiety. Analyses of covariance revealed that recipients with recent tachyarrhythmia (F = 7.675 df = 9/100, P = 0.007) as well as recipients with a shock history (F = 9.976, df = 9/103, P = 0.002) reported higher levels of shock anxiety than recipients with no recent tachyarrhythmia.
CONCLUSION: This study indicates that although a substantial proportion of the ICD recipients experienced some form of shock anxiety, only a relatively small proportion reported general shock anxiety. ICD recipients with recent tachyarrhythmia, in addition to recipients with shock history, appear to be at greater risk for development of shock anxiety. This implies that these recipients may profit from clinical-based strategies and interventions targeting shock anxiety. ©2012, The Authors. Journal compilation ©2012 Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2012        PMID: 22946670     DOI: 10.1111/j.1540-8159.2012.03505.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  8 in total

Review 1.  Psychological Aspects of Cardiac Care and Rehabilitation: Time to Wake Up to Sleep?

Authors:  Jonathan Gallagher; Giulia Parenti; Frank Doyle
Journal:  Curr Cardiol Rep       Date:  2015-12       Impact factor: 2.931

2.  Influence of Multimorbidity on Burden and Appropriateness of Implantable Cardioverter-Defibrillator Therapies.

Authors:  Alexandra M Hajduk; Jerry H Gurwitz; Grace Tabada; Frederick A Masoudi; David J Magid; Robert T Greenlee; Sue Hee Sung; Andrea E Cassidy-Bushrow; Taylor I Liu; Kristi Reynolds; David H Smith; Frances Fiocchi; Robert Goldberg; Thomas M Gill; Nigel Gupta; Pamela N Peterson; Claudio Schuger; Humberto Vidaillet; Stephen C Hammill; Heather Allore; Alan S Go
Journal:  J Am Geriatr Soc       Date:  2019-03-20       Impact factor: 5.562

3.  Longitudinal changes in quality of life following ICD implant and the impact of age, gender, and ICD shocks: observations from the INTRINSIC RV trial.

Authors:  Rakesh Gopinathannair; Darin R Lerew; Natalie J Cross; Samuel F Sears; Scott Brown; Brian Olshansky
Journal:  J Interv Card Electrophysiol       Date:  2017-02-20       Impact factor: 1.900

4.  Age, Sex, and Remote Monitoring Differences in Device Acceptance for Patients With Implanted Cardioverter Defibrillators in Canada.

Authors:  Jessica Ng; Samuel F Sears; Derek V Exner; Lucy Reyes; Xenia Cravetchi; Peggy Cassidy; James Morton; Carmen Lohrenz; Aaron Low; Roopinder K Sandhu; Robert S Sheldon; Satish R Raj
Journal:  CJC Open       Date:  2020-06-16

5.  The Predictor Roles of Spiritual Well-Being, Healthcare Professionals' Support and Shock Anxiety in Implantable Cardioverter-Defibrillator Device Acceptance.

Authors:  Nilofar Pasyar; Masoume Rambod; Alireza Zare; Mohammad Hossein Nikoo
Journal:  Malays J Med Sci       Date:  2022-06-28

6.  Sleep, Psychosocial Functioning, and Device-Specific Adjustment in Patients with Implantable Cardioverter Defibrillators (ICDs).

Authors:  Christina S McCrae; Alicia J Roth; Jessica Ford; Earl C Crew; Jamie B Conti; Richard B Berry; Samuel F Sears
Journal:  Behav Sleep Med       Date:  2014-08-30       Impact factor: 2.964

7.  Patient-reported outcomes and associations with pleural effusion in outpatients with heart failure: an observational cohort study.

Authors:  Guri H Gundersen; Tone M Norekvål; Torbjørn Graven; Hilde H Haug; Kyrre Skjetne; Jens O Kleinau; Lise T Gustad; Håvard Dalen
Journal:  BMJ Open       Date:  2017-03-20       Impact factor: 2.692

8.  Prevalence of anxiety in patients with an implantable cardioverter defibrillator: measurement equivalence of the HADS-A and the STAI-S.

Authors:  W H Emons; M Habibović; S S Pedersen
Journal:  Qual Life Res       Date:  2019-06-22       Impact factor: 4.147

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.