Literature DB >> 22941093

.VO2max is not altered by self-pacing during incremental exercise.

Weerapong Chidnok1, Fred J Dimenna, Stephen J Bailey, Mark Burnley, Daryl P Wilkerson, Anni Vanhatalo, Andrew M Jones.   

Abstract

We tested the hypothesis that incremental cycling to exhaustion that is paced using clamps of the rating of perceived exertion (RPE) elicits higher .VO2max values compared to a conventional ramp incremental protocol when test duration is matched. Seven males completed three incremental tests to exhaustion to measure .VO2max. The incremental protocols were of similar duration and included: a ramp test at 30 W min(-1) with constant cadence (RAMP1); a ramp test at 30 W min(-1) with cadence free to fluctuate according to subject preference (RAMP2); and a self-paced incremental test in which the power output was selected by the subject according to prescribed increments in RPE (SPT). The subjects also completed a .VO2max 'verification' test at a fixed high-intensity power output and a 3-min all-out test. No difference was found for .VO2max between the incremental protocols (RAMP1 = 4.33 ± 0.60 L min(-1); RAMP2 = 4.31 ± 0.62 L min(-1); SPT = 4.36 ± 0.59 L min(-1); P > 0.05) nor between the incremental protocols and the peak.VO2max measured during the 3-min all-out test (4.33 ± 0.68 L min(-1)) or the .VO2max measured in the verification test (4.32 ± 0.69 L min(-1)). The integrated electromyogram, blood lactate concentration, heart rate and minute ventilation at exhaustion were not different (P > 0.05) between the incremental protocols. In conclusion, when test duration is matched, SPT does not elicit a higher .VO2max compared to conventional incremental protocols. The striking similarity of .VO2max measured across an array of exercise protocols indicates that there are physiological limits to the attainment of .VO2max that cannot be exceeded by self-pacing.

Entities:  

Mesh:

Year:  2012        PMID: 22941093     DOI: 10.1007/s00421-012-2478-6

Source DB:  PubMed          Journal:  Eur J Appl Physiol        ISSN: 1439-6319            Impact factor:   3.078


  39 in total

1.  New ideas on limitations to VO2max.

Authors:  P D Wagner
Journal:  Exerc Sport Sci Rev       Date:  2000-01       Impact factor: 6.230

2.  Low frequency of the "plateau phenomenon" during maximal exercise in elite British athletes.

Authors:  M Doherty; L Nobbs; T D Noakes
Journal:  Eur J Appl Physiol       Date:  2003-05-21       Impact factor: 3.078

3.  A 3-min all-out test to determine peak oxygen uptake and the maximal steady state.

Authors:  Mark Burnley; Jonathan H Doust; Anni Vanhatalo
Journal:  Med Sci Sports Exerc       Date:  2006-11       Impact factor: 5.411

4.  Determination of critical power using a 3-min all-out cycling test.

Authors:  Anni Vanhatalo; Jonathan H Doust; Mark Burnley
Journal:  Med Sci Sports Exerc       Date:  2007-03       Impact factor: 5.411

Review 5.  Critical power: implications for determination of V˙O2max and exercise tolerance.

Authors:  Andrew M Jones; Anni Vanhatalo; Mark Burnley; R Hugh Morton; David C Poole
Journal:  Med Sci Sports Exerc       Date:  2010-10       Impact factor: 5.411

6.  Maximal oxygen uptake as a parametric measure of cardiorespiratory capacity.

Authors:  Megan N Hawkins; Peter B Raven; Peter G Snell; James Stray-Gundersen; Benjamin D Levine
Journal:  Med Sci Sports Exerc       Date:  2007-01       Impact factor: 5.411

7.  Is there a disassociation of maximal oxygen consumption and maximal cardiac output?

Authors:  S D McCole; A M Davis; P T Fueger
Journal:  Med Sci Sports Exerc       Date:  2001-08       Impact factor: 5.411

8.  Comparison of a continuous and discontinuous graded treadmill test for maximal oxygen uptake.

Authors:  M G Maksud; K D Coutts
Journal:  Med Sci Sports       Date:  1971

9.  The maximally attainable VO2 during exercise in humans: the peak vs. maximum issue.

Authors:  J R Day; H B Rossiter; E M Coats; A Skasick; B J Whipp
Journal:  J Appl Physiol (1985)       Date:  2003-07-11

10.  Optimizing the exercise protocol for cardiopulmonary assessment.

Authors:  M J Buchfuhrer; J E Hansen; T E Robinson; D Y Sue; K Wasserman; B J Whipp
Journal:  J Appl Physiol Respir Environ Exerc Physiol       Date:  1983-11
View more
  16 in total

1.  Individual versus Standardized Running Protocols in the Determination of VO2max.

Authors:  Paula F Sperlich; Hans-Christer Holmberg; Jennifer L Reed; Christoph Zinner; Joachim Mester; Billy Sperlich
Journal:  J Sports Sci Med       Date:  2015-05-08       Impact factor: 2.988

2.  Inconsistent approach to evaluating studies and selective interpretation of data reveals lack of objectivity and undermines repeated attempts to discredit SPV.

Authors:  Lauren A Jenkins; Alexis R Mauger; James G Hopker
Journal:  Eur J Appl Physiol       Date:  2017-03-27       Impact factor: 3.078

3.  .VO2max is altered by self-pacing during incremental exercise.

Authors:  Alexis R Mauger
Journal:  Eur J Appl Physiol       Date:  2012-12-11       Impact factor: 3.078

Review 4.  Maximal oxygen consumption in healthy humans: theories and facts.

Authors:  Guido Ferretti
Journal:  Eur J Appl Physiol       Date:  2014-07-02       Impact factor: 3.078

5.  Ramp-incremented and RPE-clamped test protocols elicit similar VO2max values in trained cyclists.

Authors:  Allison M Straub; Adrian W Midgley; Gerald S Zavorsky; Angela R Hillman
Journal:  Eur J Appl Physiol       Date:  2014-04-29       Impact factor: 3.078

6.  Validity of a perceptually-regulated step test protocol for assessing cardiorespiratory fitness in healthy adults.

Authors:  Hunter Bennett; Kade Davison; Gaynor Parfitt; Roger Eston
Journal:  Eur J Appl Physiol       Date:  2016-10-05       Impact factor: 3.078

7.  Modality determines VO2max achieved in self-paced exercise tests: validation with the Bruce protocol.

Authors:  Nicholas J Hanson; Cory M Scheadler; Taylor L Lee; Noah C Neuenfeldt; Timothy J Michael; Michael G Miller
Journal:  Eur J Appl Physiol       Date:  2016-05-05       Impact factor: 3.078

8.  Pacing strategy during the final stage of a self-paced V̇O₂max (SPV) test does not affect maximal oxygen uptake.

Authors:  Nicholas J Hanson; Carter R Reid; Kaitlin M Cornwell; Taylor L Lee; Cory M Scheadler
Journal:  Eur J Appl Physiol       Date:  2017-06-05       Impact factor: 3.078

9.  Increased cerebral blood flow supports a single-bout postexercise benefit to executive function: evidence from hypercapnia.

Authors:  Benjamin Tari; James J Vanhie; Glen R Belfry; J Kevin Shoemaker; Matthew Heath
Journal:  J Neurophysiol       Date:  2020-08-05       Impact factor: 2.714

10.  The effect of trial familiarisation on the validity and reproducibility of a field-based self-paced VO2max test.

Authors:  W Lim; D Lambrick; A R Mauger; B Woolley; J Faulkner
Journal:  Biol Sport       Date:  2016-07-02       Impact factor: 2.806

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.