Literature DB >> 22939660

Rapid-test sensitivity for novel swine-origin pandemic influenza A.

Chun-Fu Tai1, Chun-Yi Lu, Pei-Lan Shao, Ping-Ing Lee, Luan-Yin Chang, Li-Min Huang.   

Abstract

BACKGROUND/
PURPOSE: Rapid diagnosis of influenza was important in the global pandemic influenza A/H1N1 outbreak. The QuickVue Influenza A+B test is one of the most common tests for rapid diagnosis of influenza. We evaluated the sensitivity and specificity of the test in children.
METHODS: We collected data from 970 patients with influenza-like illness who received rapid influenza antigen tests using the QuickVue Influenza A+B test as well as viral isolation. We compared the results with that of viral isolation and reverse-transcriptase polymerase chain reaction (RT-PCR) assays.
RESULTS: Based on viral culture, the QuickVue Influenza A+B test had an overall sensitivity of 0.82 (419/513) and specificity of 0.99 (70/71), with a positive predictive value (PPV) of 0.74 (419/563) and a negative predictive value (NPV) of 0.77 (313/407). The sensitivity of QuickVue was significantly higher in specimens with high viral loads. If the viral loads were less than 10(6), the sensitivity of QuickVue was 0.62, while the sensitivity of QuickVue was 0.88 if the viral loads were higher than 10(6) (p<0.001). Logistic regression analysis showed that higher viral loads correlated with positive QuickVue results (p<0.001). On the first day of fever, the sensitivity of QuickVue was only 0.67; on the second day, the sensitivity was 0.86; on the third day, the sensitivity was 0.98, and on the fourth day, the sensitivity was 0.90. The sensitivity is significantly higher on days 2-3 in comparison with the first day of fever (p<0.05). We calculated the correlation of viral load and fever days, and the result showed higher mean viral load on the second and third days of fever. Age did not affect the sensitivity.
CONCLUSION: In children, the sensitivity of QuickVue Influenza A+B test was 0.82. In addition, the sensitivity was significantly elevated in the higher viral load group and on the third day of fever.
Copyright © 2012. Published by Elsevier B.V.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22939660     DOI: 10.1016/j.jfma.2011.06.018

Source DB:  PubMed          Journal:  J Formos Med Assoc        ISSN: 0929-6646            Impact factor:   3.282


  1 in total

1.  Performance of rapid influenza diagnostic tests (QuickVue) for influenza A and B Infection in India.

Authors:  P A Koul; H Mir; M A Bhat; U H Khan; M M Khan; M S Chadha; R B Lal
Journal:  Indian J Med Microbiol       Date:  2015-02       Impact factor: 0.985

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.