Literature DB >> 22939157

Magnetic solid-phase extraction of five pyrethroids from environmental water samples followed by ultrafast liquid chromatography analysis.

Xi Yu1, Ying Sun, Chunzhu Jiang, Xiumin Sun, Yan Gao, Yuanpeng Wang, Hanqi Zhang, Daqian Song.   

Abstract

In this study, the polystyrene-coated magnetic nanoparticles (MNPs/PSt) were successfully prepared and characterized by Fourier transform infrared spectroscopy, transmission electron microscopy and vibrating sample magnetometry. The as-prepared MNPs/PSt were used as the adsorbent in magnetic solid phase extraction of five pyrethroids, including lambda-cyhalothrin, deltamethrin, esfenvalerate, permethrin, bifenthrin, in environmental water samples. The five pyrethroids were determined by ultra fast liquid chromatography-ultraviolet spectrometry. The influencing factors, including amount of MNPs/Pst, extraction time, pH value, type and volume of desorption solvent and desorption time, were examined and optimized. The extraction recoveries obtained with merely 50mg of MNPs/Pst were very satisfactory. The whole extraction process could be completed within 0.5h. The MNPs/PSt can be reused after an easy washing process. Thus, a simple, green, economical, time saving and effective method for pyrethroids analysis in environmental water samples was established. A high enrichment factor of 500 was achieved and the limits of detection for lambda-cyhalothrin, deltamethrin, esfenvalerate, permethrin, bifenthrin were 0.015±0.001 ng mL(-1), 0.012±0.001 ng mL(-1), 0.026±0.001 ng mL(-1), 0.020±0.001 ng mL(-1), 0.013±0.001 ng mL(-1), respectively. Recoveries obtained by analyzing spiked water samples at three concentration levels (0.100±0.001 ng mL(-1), 1.000±0.001 ng mL(-1), 10.000±0.001 ng mL(-1)) were between 78.97±8.38% and 96.05±8.38%. The standard curves for the five pyrethroids showed good linearity with the correlation coefficients in the range of 0.9994-0.9999. The intra-day and inter-day precision were satisfactory with the RSDs in the range of 2.05-5.52% and 2.73-8.38%, respectively.
Copyright © 2012 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22939157     DOI: 10.1016/j.talanta.2012.07.022

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  3 in total

1.  Magnetic solid-phase extraction of polycyclic aromatic hydrocarbons using a graphene oxide/Fe3O4@polystyrene nanocomposite.

Authors:  Amirhassan Amiri; Mehdi Baghayeri; Mina Sedighi
Journal:  Mikrochim Acta       Date:  2018-07-28       Impact factor: 5.833

2.  A polyurethane-based thin film for solid phase microextraction of pyrethroid insecticides.

Authors:  Xianbin Zhu; Rimao Hua; Dong Zhang; Xiangwei Wu; Yi Wang; Jiaying Xue
Journal:  Mikrochim Acta       Date:  2019-08-02       Impact factor: 5.833

3.  Dispersive Solid-Phase Extraction using Magnetic Carbon Nanotube Composite for the Determination of Emergent Mycotoxins in Urine Samples.

Authors:  Natalia Arroyo-Manzanares; Rosa Peñalver-Soler; Natalia Campillo; Pilar Viñas
Journal:  Toxins (Basel)       Date:  2020-01-15       Impact factor: 4.546

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.