Literature DB >> 22937531

Disposable electrochemical immunosensor for simultaneous assay of a panel of breast cancer tumor markers.

Shenguang Ge1, Feng Yu, Lei Ge, Mei Yan, Jinghua Yu, Dairong Chen.   

Abstract

The multiplexed immunosensor array was fabricated on a carbon electrode array containing three graphite working electrodes, which was prepared with screen-printed technology. This immunosensor was achieved using graphene (GR) to modify the immunosensor surface for accelerating electron transfer. The in situ synthesis of AuNPs on GR modified electrode surface aimed at the immobilization of capture antibody (Ab(1)). With a sandwich-type immunoreaction, the alkaline phosphatase (ALP)-labeled antibody (Ab(2)) functionalized Au cluster (AuCs)/GR was captured on the immunosensor surface to catalyze the hydrolysis of 3-indoxyl phosphate in substrate, which produced an indoxyl intermediate to reduce Ag ion. The silver deposition process was catalyzed by both ALP and AuCs/GR, which amplified the detection signal. The deposited silver was then measured by anodic linear sweep voltammetric stripping analysis in KCl solution. The increase of stripping peak currents was proportional to the logarithm value of the CA 153, CA 125 and CEA concentration in the range 5.0 × 10(-3) to 50 U mL(-1) for CA 153, 1.0 × 10(-3) to 100 U mL(-1) for CA 125, and 4.0 × 10(-3) to 200 ng mL(-1) for CEA, with a limit detection of 1.5 × 10(-3) U mL(-1) for CA 153, 3.4 × 10(-4) U mL(-1) for CA 125, and 1.2 × 10(-3) ng mL(-1) for CEA. The disposable immunosensor array and simple detection method for fast measurement of a panel of tumor markers avoided cross-talk and the need for deoxygenation for the electrochemical immunoassay, and showed significant clinical value for application in cancer screening, providing great potential for convenient point-of-care testing and commercial application.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22937531     DOI: 10.1039/c2an35967g

Source DB:  PubMed          Journal:  Analyst        ISSN: 0003-2654            Impact factor:   4.616


  2 in total

Review 1.  Multiplexed Electrochemical Immunosensors for Clinical Biomarkers.

Authors:  Paloma Yáñez-Sedeño; Susana Campuzano; José M Pingarrón
Journal:  Sensors (Basel)       Date:  2017-04-27       Impact factor: 3.576

Review 2.  Electrochemical Signal Substance for Multiplexed Immunosensing Interface Construction: A Mini Review.

Authors:  Jiejie Feng; Changshun Chu; Zhanfang Ma
Journal:  Molecules       Date:  2022-01-02       Impact factor: 4.411

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.