Literature DB >> 22937511

Reconstruction of complex orbital fracture with titanium implants.

Wen-Shu Yi1, Xue-Liang Xu, Jian-Rong Ma, Xin-Rong Ou.   

Abstract

AIM: To evaluate the effectiveness and safety of complex orbital fracture reconstruction with titanium implants.
METHODS: A retrospective review of 46 patients treated with complex orbital fractures reconstruction using titanium implants from January 2005 to December 2008 was conducted. The following data were recorded: age, gender, mechanism of injury, preoperative and postoperative orbital CT, visual acuity, diplopia, ocular motility and Hertel exophthalmometer.
RESULTS: The most common cause was motor vehicle accident (47.8%), followed by industrial injury (30.4%). All patients had improved appearance after operation and CT scan at one week after operation showed the fracture defects of orbit and neighboring areas had been reconstructed. Forty-six cases had various degrees of enophthalmos before operation. Among them, 32 cases were completely corrected, 11 cases improved obviously and 3 cases had no improvement after operation. Thirty-six patients with visual acuity ≥20/60 revealed diplopia of various degrees, including 26 patients had diplopia in right ahead and/or reading positions. At the sixth month after operation, diplopia disappeared in five patients, 7 patients still had diplopia in right ahead and/or reading positions, 14 patients had diplopia in positions rather than right ahead and reading positions (<20°) and ten patients had diplopia only at peripheral gazing (>20°). All patients had various degrees of ocular motility disorders before operation. At the sixth month after operation, eyeball movement disorder disappeared in 9 patients, 31 patients showed improvement and 6 patients had no improvement. Complications of implant infection, rejection and displacement were not reported after operation.
CONCLUSION: The application of titanium implants in the repair of complex orbital fractures greatly improves the appearance and functional results, which is a favorable material for plastic surgery of complex orbital fracture.

Entities:  

Keywords:  complex orbital fractures; reconstruction; titanium

Year:  2012        PMID: 22937511      PMCID: PMC3428547          DOI: 10.3980/j.issn.2222-3959.2012.04.16

Source DB:  PubMed          Journal:  Int J Ophthalmol        ISSN: 2222-3959            Impact factor:   1.779


  19 in total

1.  Rigid fixation of internal orbital fractures.

Authors:  R D Glassman; P N Manson; C A Vanderkolk; N T Iliff; M J Yaremchuk; P Petty; C R Defresne; B L Markowitz
Journal:  Plast Reconstr Surg       Date:  1990-12       Impact factor: 4.730

2.  Titanium mesh in orbital wall reconstruction.

Authors:  A W Sugar; M Kuriakose; N D Walshaw
Journal:  Int J Oral Maxillofac Surg       Date:  1992-06       Impact factor: 2.789

3.  Individually preformed titanium mesh implants for a true-to-original repair of orbital fractures.

Authors:  R Schön; M C Metzger; C Zizelmann; N Weyer; R Schmelzeisen
Journal:  Int J Oral Maxillofac Surg       Date:  2006-10-17       Impact factor: 2.789

4.  Long-term results after primary restoration of the orbital floor.

Authors:  J Friesenecker; R Dammer; M Moritz; H Niederdellmann
Journal:  J Craniomaxillofac Surg       Date:  1995-02       Impact factor: 2.078

5.  Reconstruction of internal orbital fractures with Vitallium mesh.

Authors:  L A Sargent; K D Fulks
Journal:  Plast Reconstr Surg       Date:  1991-07       Impact factor: 4.730

6.  Orbital floor repair with titanium mesh screen.

Authors:  D J Mackenzie; B Arora; J Hansen
Journal:  J Craniomaxillofac Trauma       Date:  1999

7.  Safety of titanium mesh for orbital reconstruction.

Authors:  Andrew J L Gear; Adam Lokeh; Jeffrey H Aldridge; Mark R Migliori; Charles I Benjamin; Warren Schubert
Journal:  Ann Plast Surg       Date:  2002-01       Impact factor: 1.539

8.  Diplopia and enophthalmos after surgical repair of blowout fracture.

Authors:  Banu M Hoşal; Randall L Beatty
Journal:  Orbit       Date:  2002-03

Review 9.  Optimizing the management of orbitozygomatic fractures.

Authors:  R J Rohrich; L H Hollier; D Watumull
Journal:  Clin Plast Surg       Date:  1992-01       Impact factor: 2.017

10.  A consecutive case review of orbital blowout fractures and recommendations for comprehensive management.

Authors:  Hiroki Yano; Motoi Nakano; Kuniaki Anraku; Yuichi Suzuki; Hiroyuki Ishida; Ryuichi Murakami; Akiyoshi Hirano
Journal:  Plast Reconstr Surg       Date:  2009-08       Impact factor: 4.730

View more
  2 in total

1.  The clinical characteristics of alcohol-related ocular rupture.

Authors:  Liu Jian-Wei; Hu Zhen-Bo; Wang Shu-Na; Zhu Yu-Guang; Deng Ai-Jun
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2014-10-14       Impact factor: 3.117

Review 2.  Review of Orbital Fractures in an Urban Level I Trauma Center.

Authors:  Dina Amin; Kareem Al-Mulki; Oswaldo A Henriquez; Angela Cheng; Steven Roser; Shelly Abramowicz
Journal:  Craniomaxillofac Trauma Reconstr       Date:  2020-05-08
  2 in total