Literature DB >> 2293635

Stability of initial fixation of the tibial component in cementless total knee arthroplasty.

H Shimagaki1, J E Bechtold, R E Sherman, R B Gustilo.   

Abstract

This study measured the vertical displacement of three kinds of cementless tibial components [Porous Coated Anatomical (PCA), Tricon, and Whiteside], under eccentric loading up to 2,225 N. Displacement between the tibial tray and the proximal tibia was measured with linear variable differential transformers at the anterior and posterior side when anteriorly or posteriorly loaded, and at the medial and lateral side when medially or laterally loaded. The general pattern of motion was sinking at the loaded side and lift-off at the opposite side. Lift-off opposite the loaded side was fairly small for all components at all measurement sites. Among the three components, the Whiteside showed the smallest displacements. The Tricon (when anteriorly or posteriorly loaded), and the PCA (when medially or laterally loaded) showed sinking at the loaded side. Anterior screw fixation of the PCA was not effective in preventing anterior lift-off. The tilting motion of the tibial components observed in this study implies instability of the initial fixation, which could possibly compromise bony ingrowth. Furthermore, this tilting could cause uneven distribution of load, and potentially result in fracture of the underlying bone.

Entities:  

Mesh:

Year:  1990        PMID: 2293635     DOI: 10.1002/jor.1100080108

Source DB:  PubMed          Journal:  J Orthop Res        ISSN: 0736-0266            Impact factor:   3.494


  3 in total

1.  Fixation of the tibial component in knee arthroplasty after six weeks.

Authors:  S Toksvig-Larsen; L Ryd; A Lindstrand
Journal:  Int Orthop       Date:  1995       Impact factor: 3.075

2.  Acute, recurrent total knee dislocation: Polyethylene dislocation and malreduction.

Authors:  Samuel F Thompson; Blake E Peterson; Ajay Aggarwal
Journal:  Arthroplast Today       Date:  2015-03-20

3.  Hybrid total knee arthroplasty revisited: midterm followup of hybrid versus cemented fixation in total knee arthroplasty.

Authors:  Christopher E Pelt; Jeremy M Gililland; Justin Doble; Benjamin M Stronach; Christopher L Peters
Journal:  Biomed Res Int       Date:  2013-09-25       Impact factor: 3.411

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.