Literature DB >> 22935958

The influence of haemodialysis on haemodynamic measurements using transpulmonary thermodilution in patients with septic shock: an observational study.

Anita Pathil1, Wolfgang Stremmel, Vedat Schwenger, Christoph Eisenbach.   

Abstract

CONTEXT: Patients with sepsis frequently present with acute renal failure requiring intermittent renal replacement therapy and haemodynamic monitoring. To date, the effect of haemodialysis on PiCCO monitoring has not been determined.
OBJECTIVE: To determine the effect of haemodialysis on the measurement of haemodynamic variables using transpulmonary thermodilution.
DESIGN: Prospective observational study.
SETTING: Medical ICU in a university hospital. PATIENTS: Thirty patients with sepsis and acute renal failure undergoing intermittent haemodialysis.
INTERVENTIONS: None. MAIN OUTCOME MEASURES: Cardiac index, global end-diastolic volume index and extravascular lung water index measured with or without haemodialysis.
RESULTS: Significant correlations were found for all variables measured with and without haemodialysis (r = 0.55 to 0.91, P < 0.01). Measurements of cardiac index without and with haemodialysis were significantly different [4.71 vs. 4.18 lmin(-1)m(-2), difference -0.54 (SD 0.70), 95% confidence interval (CI) -0.80 to -0.28; P < 0.01], as were values of global end-diastolic volume index without and with haemodialysis [864.8 vs. 775.3 ml m(-2), difference -89.5 (SD 191.8), 95% CI -161.2 to -17.9; P = 0.02]. Measurements of extravascular lung water index without and with haemodialysis did not differ significantly [10.3 vs. 10.0 ml kg(-1), difference -0.3 (SD 2.0), 95% CI -1.1 to 0.5; P = 0.42].
CONCLUSION: Although significant correlations were found for cardiac index, global end-diastolic volume index and extravascular lung water index with and without haemodialysis, cardiac index and global end-diastolic volume index were significantly reduced during haemodialysis, but not extravascular lung water index, when measured by the PiCCO system in patients with septic shock. Although differences were small, the variability of within-patient differences may be clinically important and care should be taken in relying solely on such measurements.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 22935958     DOI: 10.1097/EJA.0b013e328358543a

Source DB:  PubMed          Journal:  Eur J Anaesthesiol        ISSN: 0265-0215            Impact factor:   4.330


  5 in total

1.  Development of a Physiologically Based Pharmacokinetic Modelling Approach to Predict the Pharmacokinetics of Vancomycin in Critically Ill Septic Patients.

Authors:  Christian Radke; Dagmar Horn; Christian Lanckohr; Björn Ellger; Michaela Meyer; Thomas Eissing; Georg Hempel
Journal:  Clin Pharmacokinet       Date:  2017-07       Impact factor: 6.447

2.  Effect of hemodialysis on impedance cardiography (electrical velocimetry) parameters in children.

Authors:  Meike Wilken; Jun Oh; Hans O Pinnschmidt; Dominique Singer; Martin E Blohm
Journal:  Pediatr Nephrol       Date:  2019-12-14       Impact factor: 3.714

3.  Transpulmonary thermodilution (TPTD) before, during and after Sustained Low Efficiency Dialysis (SLED). A Prospective Study on Feasibility of TPTD and Prediction of Successful Fluid Removal.

Authors:  Wolfgang Huber; Stephan Fuchs; Andreas Minning; Claudius Küchle; Marlena Braun; Analena Beitz; Caroline Schultheiss; Sebastian Mair; Veit Phillip; Sebastian Schmid; Roland M Schmid; Tobias Lahmer
Journal:  PLoS One       Date:  2016-04-18       Impact factor: 3.240

4.  Sustained low efficiency dialysis should not be interrupted for performing transpulmonary thermodilution measurements.

Authors:  Stefanie Geith; Lynne Stecher; Christian Rabe; Stefan Sack; Florian Eyer
Journal:  Ann Intensive Care       Date:  2018-11-23       Impact factor: 6.925

5.  CRRT influences PICCO measurements in febrile critically ill patients.

Authors:  Qiancheng Xu; Yuhan Cao; Weihua Lu; Jianguo Li
Journal:  Open Med (Wars)       Date:  2022-02-14
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.