Literature DB >> 22933676

Distraction osteogenesis using a monolateral external fixator for infected non-union of the femur with bone loss.

Sumit Arora1, Sumit Batra, Vikas Gupta, Aman Goyal.   

Abstract

PURPOSE: To review records of 15 patients who underwent distraction osteogenesis/bone transport using a monolateral external fixator for infected non-union of the femoral shaft.
METHODS: 13 men and 2 women aged 18 to 47 years underwent adequate debridement and resection of nonviable bone, followed by bone transport using a monolateral external fixator for infected non-union of the femoral shaft with bone loss. All patients had a bone defect of >5 cm. The lengthening index, radiographic consolidation index, functional status, bone healing, and various problems, obstacles and complications encountered during the treatment were assessed.
RESULTS: The patients had undergone a mean of 2.9 (range, 1-7) surgical procedures before presentation. The mean duration from trauma to presentation was 7.7 (range, 6-18) months. The mean bone defect after adequate resection/debridement was 7.9 (range, 5.5-17) cm. The mean treatment duration was 7.3 (range, 5-15) months. The mean lengthening index was 12.3 (range, 11.5-15) days/cm. The mean treatment index was 27.9 (range, 24-40) days/cm. The mean follow-up duration was 19.3 (range, 15-41) months. Functional outcome was excellent in 5, good in 8, and fair in 2 patients. All patients achieved bone union and eradication of infection. Bone healing was excellent in 12 and good in 3 patients. All the patients were satisfied with the procedure. None had neurovascular complications, joint subluxations, or refracture of the regenerated bone. True complications encountered included knee stiffness (n=6) and knee flexion contracture (n=1). Three patients with an initial bone defect of >10 cm had delayed union and underwent bone grafting.
CONCLUSION: Bone transport using a monolateral external fixator is safe and effective for treating infected non-union of the femoral shaft.

Entities:  

Mesh:

Year:  2012        PMID: 22933676     DOI: 10.1177/230949901202000210

Source DB:  PubMed          Journal:  J Orthop Surg (Hong Kong)        ISSN: 1022-5536            Impact factor:   1.118


  11 in total

1.  Treatment of atrophic femoral non-unions according to the diamond concept: Results of one- and two-step surgical procedure.

Authors:  Arash Moghaddam; Benjamin Thaler; Thomas Bruckner; Michael Tanner; Gerhard Schmidmaier
Journal:  J Orthop       Date:  2016-11-02

2.  Management of complex femoral nonunion with monorail external fixator: A prospective study.

Authors:  Hemendra Kumar Agrawal; Mohit Garg; Balvinder Singh; Ashish Jaiman; Vipin Khatkar; Shailender Khare; Sumit Batra; Vinod Kumar Sharma
Journal:  J Clin Orthop Trauma       Date:  2016-06-08

3.  A Novel technique of three-ring Ilizarov fixator frame in gap non-union of tibia.

Authors:  Ajit Chalak; Sushmit Singh; Sunil Shetty; Sachin Kale; Pankaj Singh; Ashok Ghodke
Journal:  J Clin Orthop Trauma       Date:  2021-10-19

4.  Infected nonunion of tibia and femur treated by bone transport.

Authors:  Peng Yin; Lihai Zhang; Tongtong Li; Licheng Zhang; Guoqi Wang; Jiantao Li; Jianheng Liu; Jianfeng Zhou; Qun Zhang; Peifu Tang
Journal:  J Orthop Surg Res       Date:  2015-04-10       Impact factor: 2.359

Review 5.  Allograft Bone as Antibiotic Carrier.

Authors:  Heinz Winkler; Peter Haiden
Journal:  J Bone Jt Infect       Date:  2017-01-01

6.  Treatment of chronic orthopaedic infection.

Authors:  Heinz Winkler
Journal:  EFORT Open Rev       Date:  2017-05-11

7.  Comparision of Ilizarov Ring Fixator and Rail Fixator in Infected Nonunion of Long Bones: A Retrospective Followup Study.

Authors:  Ravisha Bhardwaj; Jaspal Singh; Rajesh Kapila; Randhir S Boparai
Journal:  Indian J Orthop       Date:  2019 Jan-Feb       Impact factor: 1.251

Review 8.  An engineering review of external fixators.

Authors:  P L N Fernando; Aravinda Abeygunawardane; Pci Wijesinghe; Parakrama Dharmaratne; Pujitha Silva
Journal:  Med Eng Phys       Date:  2021-11-04       Impact factor: 2.242

Review 9.  Use of external fixators in developing countries: a short socioeconomic analysis.

Authors:  Pathmanathan Cinthuja; P C I Wijesinghe; Pujitha Silva
Journal:  Cost Eff Resour Alloc       Date:  2022-03-29

10.  Surgical Treatment of an Infected Nonunion of the Middle Third of the Femur Associated with Femoral Shortening in a Hemophilia Patient.

Authors:  Ahmet Salduz; Özcan Kaya; Halil İbrahim Balci; Turgut Akgul; Fatih Dikici; Bülent Zülfikar; Mehmet Kocaoğlu
Journal:  Case Rep Orthop       Date:  2016-03-17
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.