Literature DB >> 22928688

Transcranial Doppler with bubble study as a method to detect extracardiac right-to-left shunts in patients with ischemic stroke.

Stephen A Goutman1, Irene L Katzan, Rishi Gupta.   

Abstract

BACKGROUND AND
PURPOSE: Paradoxical embolism through extracardiac right-to-left shunts (ECRLS) may represent an under-detected stroke mechanism. Stroke patients without evidence of cardiac right-to-left shunt (RLS) on echocardiogram may benefit from transcranial Doppler with bubble study (TCD-b) to aid in recognition of stroke etiology. This study assesses the usefulness of TCD-b in the stroke evaluation.
METHODS: Retrospective cohort study of consecutive patients undergoing TCD-b performed in our neurovascular laboratory from February 2005 to August 2009. Echocardiography results were reviewed in patients with positive TCD-b. Detailed medical record review was performed on patients with positive TCD-b and negative echocardiogram findings for RLS.
RESULTS: Of 502 patients undergoing TCD-b, 48.4% (n = 243) had a positive study suggesting the presence of RLS. Of these, 59.2% (n = 144) had an echocardiogram demonstrating a cardiac RLS, 26% (n = 63) had echocardiograms without evidence of cardiac RLS, and 14.8% (n = 36) had no echocardiogram. Data on the evaluation to determine source of potential shunting in patients with discrepant findings was available in 11(17.5%). Of these, 63.6% (7/11) had potential mechanisms for positive TCD-b: one pulmonary arteriovenous malformation (AVM), one arteriovenous fistula thrombus, one parietal AVM, and four had malignancy.
CONCLUSIONS: TCD-bubble studies may prove useful in uncovering treatable causes of stroke.
Copyright © 2012 by the American Society of Neuroimaging.

Entities:  

Keywords:  Transcranial doppler; cryptogenic stroke; shunting

Mesh:

Substances:

Year:  2012        PMID: 22928688     DOI: 10.1111/j.1552-6569.2012.00738.x

Source DB:  PubMed          Journal:  J Neuroimaging        ISSN: 1051-2284            Impact factor:   2.486


  6 in total

1.  The RoPE Score and Right-to-Left Shunt Severity by Transcranial Doppler in the CODICIA Study.

Authors:  Benjamin S Wessler; David M Kent; David E Thaler; Robin Ruthazer; Jennifer S Lutz; Joaquín Serena
Journal:  Cerebrovasc Dis       Date:  2015-07-11       Impact factor: 2.762

2.  Relation of Patent Foramen Ovale to Acute Mountain Sickness.

Authors:  Brian H West; Rubine Gevorgyan Fleming; Bashar Al Hemyari; Pooya Banankhah; Kenneth Meyer; Leslie H Rozier; Linda S Murphy; Alexandra C Coluzzi; Joshua L Rusheen; Preetham Kumar; David Elashoff; Jonathan M Tobis
Journal:  Am J Cardiol       Date:  2019-03-18       Impact factor: 2.778

3.  Ischemic stroke patients with active malignancy or extracardiac shunts are more likely to have a right-to-left shunt found by TCD than echocardiogram.

Authors:  Adam de Havenon; Anne Moore; Ali Sultan-Qurraie; Jennifer J Majersik; Greg Stoddard; David Tirschwell
Journal:  Transl Stroke Res       Date:  2015-07-25       Impact factor: 6.829

4.  Frequency of Patent Foramen Ovale and Migraine in Patients With Cryptogenic Stroke.

Authors:  Brian H West; Nabil Noureddin; Yakov Mamzhi; Christopher G Low; Alexandra C Coluzzi; Evan J Shih; Rubine Gevorgyan Fleming; Jeffrey L Saver; David S Liebeskind; Andrew Charles; Jonathan M Tobis
Journal:  Stroke       Date:  2018-04-10       Impact factor: 7.914

5.  A comparison of contrast transthoracic echocardiography and contrast transcranial Doppler in cryptogenic stroke patients with patent foramen ovale.

Authors:  Jie Chen; Luyun Chen; Wangwang Hu; Xianda Ni; Zengrui Zhang; Xiaowen Feng; Zijian Fan; Cuiping Chen; Fengzhen Qiu; Bei Shao
Journal:  Brain Behav       Date:  2019-04-02       Impact factor: 2.708

6.  Recurrent vertebrobasilar strokes and transient-ischemic attacks with challenging workup: Case report.

Authors:  Sibylle Wilfling; Mustafa Kilic; Blagovesta Tsoneva; Martin Freyer; David Olmes; Christina Wendl; Ralf A Linker; Felix Schlachetzki
Journal:  Brain Circ       Date:  2022-03-21
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.