BACKGROUND: Formation of antibodies to infliximab (ATI) inversely correlates with functional drug levels and clinical outcome. Comparison of drug levels and anti-drug antibody monitoring is hampered by lack of standardisation. AIM: To determine the correlation between three different assays for measuring infliximab and ATI. METHODS: Serum samples and spiked controls (total 62) were evaluated in a blinded way in infliximab and ATI assays developed by Sanquin Amsterdam, Netherlands (A), Laboratory for Pharmaceutical Biology, KU Leuven, Belgium (B) and a commercially available kit from Biomedical Diagnostics (BMD), Paris, France (C) performed by the University Medical Center Groningen (UMCG), Netherlands. RESULTS: All infliximab assays showed a linear quantitative correlation (Pearson r = 0.91 for A vs. B, 0.83 for A vs. C and 0.73 for B vs. C). Assay C detected infliximab in 11 samples (18%) not detected by A and B, including samples containing only ATI. All ATI assays showed a good linear correlation (Pearson r = 0.95 for A vs. B, 0.99 for A vs. C and 0.97 for B vs. C). Assay A detected ATI in five samples with low ATI that were not detected by assays B and C. Assay B did not detect ATI in three patient samples with low ATI according to assays A and C. CONCLUSIONS: There is a good correlation of infliximab and antibodies to infliximab measurements between these assays. Nevertheless, the Biomedical Diagnostics kit detected false positive infliximab levels in 18% of the samples.
BACKGROUND: Formation of antibodies to infliximab (ATI) inversely correlates with functional drug levels and clinical outcome. Comparison of drug levels and anti-drug antibody monitoring is hampered by lack of standardisation. AIM: To determine the correlation between three different assays for measuring infliximab and ATI. METHODS: Serum samples and spiked controls (total 62) were evaluated in a blinded way in infliximab and ATI assays developed by Sanquin Amsterdam, Netherlands (A), Laboratory for Pharmaceutical Biology, KU Leuven, Belgium (B) and a commercially available kit from Biomedical Diagnostics (BMD), Paris, France (C) performed by the University Medical Center Groningen (UMCG), Netherlands. RESULTS: All infliximab assays showed a linear quantitative correlation (Pearson r = 0.91 for A vs. B, 0.83 for A vs. C and 0.73 for B vs. C). Assay C detected infliximab in 11 samples (18%) not detected by A and B, including samples containing only ATI. All ATI assays showed a good linear correlation (Pearson r = 0.95 for A vs. B, 0.99 for A vs. C and 0.97 for B vs. C). Assay A detected ATI in five samples with low ATI that were not detected by assays B and C. Assay B did not detect ATI in three patient samples with low ATI according to assays A and C. CONCLUSIONS: There is a good correlation of infliximab and antibodies to infliximab measurements between these assays. Nevertheless, the Biomedical Diagnostics kit detected false positive infliximab levels in 18% of the samples.
Authors: Diana Hernández-Flórez; Lara Valor; Inmaculada de la Torre; Juan Carlos Nieto; Lina Martínez-Estupiñán; Carlos González; Francisco Javier López-Longo; Indalecio Monteagudo; Jesús Garrido; Esperanza Naredo; Luis Carreño Journal: Rheumatol Int Date: 2014-11-20 Impact factor: 2.631
Authors: Konstantinos Papamichael; Adam S Cheifetz; Gil Y Melmed; Peter M Irving; Niels Vande Casteele; Patricia L Kozuch; Laura E Raffals; Leonard Baidoo; Brian Bressler; Shane M Devlin; Jennifer Jones; Gilaad G Kaplan; Miles P Sparrow; Fernando S Velayos; Thomas Ullman; Corey A Siegel Journal: Clin Gastroenterol Hepatol Date: 2019-03-27 Impact factor: 11.382
Authors: Joseph C Marini; Jocelyn Sendecki; Freddy Cornillie; John W Popp; Shawn Black; Marion Blank; Ann Gils; Thomas Van Stappen; Dörte Hamann; Theo Rispens; Lina Thérien; Kelly Chun; Gopi Shankar Journal: AAPS J Date: 2016-09-06 Impact factor: 4.009
Authors: Thomas Billiet; Erwin Dreesen; Isabelle Cleynen; Willem-Jan Wollants; Marc Ferrante; Gert Van Assche; Ann Gils; Severine Vermeire Journal: Am J Gastroenterol Date: 2016-08-02 Impact factor: 10.864
Authors: María Chaparro; Manuel Barreiro-de Acosta; Ana Echarri; Rosendo Almendros; Jesús Barrio; Jordina Llao; Fernando Gomollón; Maribel Vera; José Luis Cabriada; Jordi Guardiola; Iván Guerra; Belén Beltrán; Oscar Roncero; David Busquets; Carlos Taxonera; Xavier Calvet; Rocío Ferreiro-Iglesias; Virginia Ollero Pena; David Bernardo; María G Donday; Ana Garre; Ana Godino; Ana Díaz; Javier P Gisbert Journal: Dig Dis Sci Date: 2018-11-13 Impact factor: 3.199