Literature DB >> 2292605

Structural consequences of transcortical holes in long bones loaded in torsion.

J A Hipp1, B C Edgerton, K N An, W C Hayes.   

Abstract

Finite element models were used to predict the structural consequences of transcortical holes through long bones loaded in torsion. Several parameters were investigated including hole size, anelastic behavior of the bone, cortical wall thickness, cortical wall symmetry, curvature along the bone's long axis and the axial length of the defect. Finite element model predictions of percent intact bone strength were compared to experimental data for sheep femora with transcortical drill holes loaded to failure in torsion. Hole size was expressed as hole diameter divided by the outer bone diameter. Linear finite element model predictions were in conservative agreement with the experimental data for large hole sizes. A transcortical hole with a diameter 50% of the outer bone diameter reduced the torsional strength by 60%. However, the linear models predict a 40% drop in strength for small holes whereas in vitro data suggest that small holes have no significant effect on strength. Models which represent non-linear anelastic behavior in bone overpredicted torsional strengths. Asymmetric cortical wall thickness and long bone bowing have minor effects, while the length of an elongated defect strongly influences the torsional strength. Strength reductions are greatest for bones with thin cortical walls.

Entities:  

Mesh:

Year:  1990        PMID: 2292605     DOI: 10.1016/0021-9290(90)90383-e

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  10 in total

1.  Strength reductions of thoracic vertebrae in the presence of transcortical osseous defects: effects of defect location, pedicle disruption, and defect size.

Authors:  M J Silva; J A Hipp; D P McGowan; T Takeuchi; W C Hayes
Journal:  Eur Spine J       Date:  1993-10       Impact factor: 3.134

2.  Effects of Ti2448 half-pin with low elastic modulus on pin loosening in unilateral external fixation.

Authors:  Kai Zheng; Xiaokang Li; Jun Fu; Xiangli Fan; Pan Wang; Yulin Hao; Shujun Li; Hongbin Fan; Zheng Guo
Journal:  J Mater Sci Mater Med       Date:  2011-04-13       Impact factor: 3.896

3.  The effect of drill hole location on load bearing capacity of long bones.

Authors:  Christopher James Yiachos; Subrata Saha
Journal:  J Orthop       Date:  2018-02-21

Review 4.  Outcomes following long head of biceps tendon tenodesis.

Authors:  Saad M AlQahtani; Ryan T Bicknell
Journal:  Curr Rev Musculoskelet Med       Date:  2016-12

5.  Rupture of the long head of the biceps brachii tendon near the musculotendinous junction in a young patient: A case report.

Authors:  Xuan Liu; Andrew Hwee Chye Tan
Journal:  World J Orthop       Date:  2020-02-18

6.  Stability with unilateral external fixation in the tibia.

Authors:  N Giotakis; B Narayan
Journal:  Strategies Trauma Limb Reconstr       Date:  2007-04

7.  Incidence and Characteristics of Humeral Shaft Fractures After Subpectoral Biceps Tenodesis.

Authors:  Archie L Overmann; Donald F Colantonio; Benjamin M Wheatley; William R Volk; Kelly G Kilcoyne; Jonathan F Dickens
Journal:  Orthop J Sports Med       Date:  2019-03-28

8.  The change in energy absorbed post removal of metalwork in a simulated paediatric long bone fracture.

Authors:  Alan J Howieson; Michael D Jones; Peter S Theobald
Journal:  J Child Orthop       Date:  2014-08-27       Impact factor: 1.548

9.  Implant-Free Subpectoral Biceps Tenodesis Is Biomechanically at Higher Risk of Spiral Fracture of the Humerus Compared With Implant-Free Suprapectoral Biceps Tenodesis.

Authors:  Arash A Dini; Joshua E Mizels; Sohale Sadeghpour; Michael J O'Brien; Felix H Savoie; Mark H Getelman
Journal:  Arthrosc Sports Med Rehabil       Date:  2020-12-26

10.  Greenstick fracture of the ulnar shaft following physical therapy in an adult: A case report.

Authors:  Yi-Chen Lin; Wei-Te Wang
Journal:  Medicine (Baltimore)       Date:  2020-12-11       Impact factor: 1.817

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.