Literature DB >> 22925922

Patient satisfaction and masticatory efficiency of single implant-retained mandibular overdentures using the stud and magnetic attachments.

Tao Cheng1, Guifeng Sun, Jingyu Huo, Xiaoji He, Yining Wang, Yan-Fang Ren.   

Abstract

OBJECTIVES: To study patient satisfaction and masticatory efficiency of single implant-retained mandibular overdentures using the stud and magnetic attachments in a randomized clinical trial with a crossover design.
METHODS: Patients received a single implant placed in the midline of the mandible and either a stud (Locator) or a magnetic (Magfit) attachment, assigned at random. Patient satisfaction, including patient comfort, speech, chewing ability and retention, and masticatory efficiency measured by chewing peanuts, were assessed before and 3 months after attachment insertion. Patient satisfaction and masticatory efficiency were evaluated again 3 months after insertion of the alternate attachment bodies. The outcomes were compared before and after insertion of the attachments and between the two types of attachments using Wilcoxon signed rank tests.
RESULTS: Patient overall satisfaction, comfort, speech, chewing ability, and retention improved significantly after insertion of both types of attachment bodies (p<0.05). Masticatory efficiencies also increased in both the Locator and the Magfit groups (p<0.05). There were no statistically significant differences in patient overall satisfaction, comfort, speech, and retention between the two types of attachments (p>0.05). The Locator attachments performed better in perceived chewing ability than the Magfit (p<0.05), but there was no statistically significant difference in masticatory efficiency between the two attachment types (p>0.05).
CONCLUSIONS: Clinical outcomes were significantly improved in single implant-retained mandibular overdentures using either the Locator or the Magfit magnetic attachments. There was no difference in masticatory efficiency between the two attachment types.
Copyright © 2012 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22925922     DOI: 10.1016/j.jdent.2012.08.011

Source DB:  PubMed          Journal:  J Dent        ISSN: 0300-5712            Impact factor:   4.379


  22 in total

1.  Summary of: attitudes of general dental practitioners to the maintenance of Locator retained implant overdentures.

Authors:  Sebastian B M Patzelt
Journal:  Br Dent J       Date:  2014-02       Impact factor: 1.626

Review 2.  The single midline implant in the edentulous mandible: a systematic review.

Authors:  Nicole Passia; Matthias Kern
Journal:  Clin Oral Investig       Date:  2014-05-29       Impact factor: 3.573

3.  Comparison of marginal bone loss and patient satisfaction in single and double-implant assisted mandibular overdenture by immediate loading.

Authors:  Sara Tavakolizadeh; Fariborz Vafaee; Masume Khoshhal; Zahra Ebrahimzadeh
Journal:  J Adv Prosthodont       Date:  2015-06-23       Impact factor: 1.904

4.  Comparison of ridge resorption and patient satisfaction in single implant-supported mandibular overdentures with conventional complete dentures: A randomised pilot study.

Authors:  Subin Km; Dheeraj Kumar Koli; Veena Jain; Gunjan Pruthi; Aditi Nanda
Journal:  J Oral Biol Craniofac Res       Date:  2020-11-25

5.  Cost-effectiveness analysis of the single-implant mandibular overdenture versus conventional complete denture: study protocol for a randomized controlled trial.

Authors:  Túlio Eduardo Nogueira; Shahrokh Esfandiari; Cláudio Rodrigues Leles
Journal:  Trials       Date:  2016-11-04       Impact factor: 2.279

6.  Corrosion behaviours of the dental magnetic keeper complexes made by different alloys and methods.

Authors:  Min-Ke Wu; Ning Song; Fei Liu; Liang Kou; Xiao-Wen Lu; Min Wang; Hang Wang; Jie-Fei Shen
Journal:  Int J Oral Sci       Date:  2016-09-29       Impact factor: 6.344

Review 7.  Implant and root supported overdentures - a literature review and some data on bone loss in edentulous jaws.

Authors:  Gunnar E Carlsson
Journal:  J Adv Prosthodont       Date:  2014-08-14       Impact factor: 1.904

8.  Single implant supported mandibular overdenture: A literature review.

Authors:  Sudhindra Mahoorkar; Srinidhi Bhat; Radhika Kant
Journal:  J Indian Prosthodont Soc       Date:  2016 Jan-Mar

9.  Comparison of masticatory efficiency, patient satisfaction for single, two, and three implants supported overdenture in the same patient: A pilot study.

Authors:  Srinidhi Bhat; Ramesh Chowdhary; Sudhindra Mahoorkar
Journal:  J Indian Prosthodont Soc       Date:  2016 Apr-Jun

10.  Satisfaction level in dental-phobic patients with implant-supported rehabilitation performed under general anaesthesia: a prospective study.

Authors:  Louise Sidenö; Rim Hmaidouch; Jan Brandt; Nadine von Krockow; Paul Weigl
Journal:  BMC Oral Health       Date:  2018-11-01       Impact factor: 2.757

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.