Effects of covered solid sorbent tube sample holders on organic vapor measurements.

B S Marpoe1, W A Groves, E G Lee, J E Slaven, M Harper.   

Abstract

A study was conducted to examine whether there are significant differences between organic vapor concentrations measured using charcoal tubes with three different configurations: uncovered sample holder (open tube), SKC, and Buck brand covered sample holders. A fractional factorial experimental design was used with the following factors and levels: vapor (n-hexane vs. m-xylene), pump type (pulsating vs. continuous), exposure profile (variable vs. constant), flow rate (30 mL/min vs. 200 mL/min), duration (30 min vs. 80 min), and sample placement (mannequin vs. free hanging). Two of each sampler configuration (six total) were placed in an exposure chamber, and a dynamic test-atmosphere generation system was used to prepare atmospheres containing approximately 12-15 ppm n-hexane or m-xylene with exposure profiles and sampling conducted according to a run sheet generated for the experimental design. A total of 24 runs were completed with six samplers per run, yielding 144 samples that were analyzed by gas chromatography/flame ionization detector. Concentration results for each pair of SKC and Buck covered sample holders were averaged and normalized by dividing by the average result for the open tube sampler from the same run to eliminate the effect of daily variation in chamber concentrations. The resulting ratio of covered sample tube holder and open tube concentrations was used as the response variable. Results of analysis of variance using the general linear model (MINITAB 16) identified statistically significant main effects and/or interactions for pump type, exposure profile, flow rate, and sample holder. However, the magnitude of the effects was generally less than 10%, and overall mean concentration ratios were 0.989 and 1.02 for the Buck and SKC sample holders, respectively. These results show good agreement between covered sample holder results and open tube measurements and demonstrate that exposure assessment errors resulting from the use of covered sorbent tube sample holders for organic vapor monitoring are relatively small (<10%) and not likely to be of practical importance.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22924985      PMCID: PMC4681745          DOI: 10.1080/15459624.2012.713763

Source DB:  PubMed          Journal:  J Occup Environ Hyg        ISSN: 1545-9624            Impact factor:   2.155


  7 in total

1.  Gas chromatography in industrial hygiene and air pollution problems.

Authors:  D E RUSHING
Journal:  Am Ind Hyg Assoc J       Date:  1958-06

2.  Laboratory evaluation of a physiologic sampling pump (PSP).

Authors:  Ming-I Brandon Lin; William A Groves; Andris Freivalds; Larry Lee; Eun Gyung Lee; James E Slaven; Martin Harper
Journal:  J Environ Monit       Date:  2010-03-19

3.  A novel physiologic sampling pump capable of rapid response to breathing.

Authors:  Larry Lee; Michael Flemmer; Eun Gyung Lee; Martin Harper; Ming-I Lin; William Groves; Andris Freivalds; James Slaven
Journal:  J Environ Monit       Date:  2009-03-03

4.  Exposure assessment by physiologic sampling pump--prediction of minute ventilation using a portable respiratory inductive plethysmograph system.

Authors:  Ming-I Lin; William A Groves; Andris Freivalds; Eun Gyung Lee; Martin Harper; James E Slaven; Larry Lee
Journal:  J Environ Monit       Date:  2008-10

5.  A convenient optimized method for the analysis of selected solvent vapors in the industrial atmosphere.

Authors:  L D White; D G Taylor; P A Mauer; R E Kupel
Journal:  Am Ind Hyg Assoc J       Date:  1970 Mar-Apr

6.  A method for the collection of air samples for analysis by gas chromatography.

Authors:  R Van Houten; G Lee
Journal:  Am Ind Hyg Assoc J       Date:  1969 Sep-Oct

7.  Charcoal sampling tubes for organic vapor analysis by gas chromatography.

Authors:  C L Fraust; E R Hermann
Journal:  Am Ind Hyg Assoc J       Date:  1966 Jan-Feb
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.