Literature DB >> 22922087

An R-peak detection method that uses an SVD filter and a search back system.

Woo-Hyuk Jung1, Sang-Goog Lee.   

Abstract

In this paper, we present a method for detecting the R-peak of an ECG signal by using an singular value decomposition (SVD) filter and a search back system. The ECG signal was detected in two phases: the pre-processing phase and the decision phase. The pre-processing phase consisted of the stages for the SVD filter, Butterworth High Pass Filter (HPF), moving average (MA), and squaring, whereas the decision phase consisted of a single stage that detected the R-peak. In the pre-processing phase, the SVD filter removed noise while the Butterworth HPF eliminated baseline wander. The MA removed the remaining noise of the signal that had gone through the SVD filter to make the signal smooth, and squaring played a role in strengthening the signal. In the decision phase, the threshold was used to set the interval before detecting the R-peak. When the latest R-R interval (RRI), suggested by Hamilton et al., was greater than 150% of the previous RRI, the method of detecting the R-peak in such an interval was modified to be 150% or greater than the smallest interval of the two most latest RRIs. When the modified search back system was used, the error rate of the peak detection decreased to 0.29%, compared to 1.34% when the modified search back system was not used. Consequently, the sensitivity was 99.47%, the positive predictivity was 99.47%, and the detection error was 1.05%. Furthermore, the quality of the signal in data with a substantial amount of noise was improved, and thus, the R-peak was detected effectively.
Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22922087     DOI: 10.1016/j.cmpb.2012.08.002

Source DB:  PubMed          Journal:  Comput Methods Programs Biomed        ISSN: 0169-2607            Impact factor:   5.428


  4 in total

1.  Set-Based Discriminative Measure for Electrocardiogram Beat Classification.

Authors:  Wei Li; Jianqing Li; Qin Qin
Journal:  Sensors (Basel)       Date:  2017-01-25       Impact factor: 3.576

2.  Automatic QRS complex detection using two-level convolutional neural network.

Authors:  Yande Xiang; Zhitao Lin; Jianyi Meng
Journal:  Biomed Eng Online       Date:  2018-01-29       Impact factor: 2.819

3.  An Adaptive and Time-Efficient ECG R-Peak Detection Algorithm.

Authors:  Qin Qin; Jianqing Li; Yinggao Yue; Chengyu Liu
Journal:  J Healthc Eng       Date:  2017-09-06       Impact factor: 2.682

4.  Spatial distribution of physiologic 12-lead QRS complex.

Authors:  Katerina Hnatkova; Irena Andršová; Ondřej Toman; Peter Smetana; Katharina M Huster; Martina Šišáková; Petra Barthel; Tomáš Novotný; Georg Schmidt; Marek Malik
Journal:  Sci Rep       Date:  2021-02-22       Impact factor: 4.379

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.