Literature DB >> 22921232

Clear corneal incisions in bimanual microincision cataract surgery: long-term wound-healing architecture.

Gian Maria Cavallini1, Luca Campi, Giulio Torlai, Matteo Forlini, Elisa Fornasari.   

Abstract

PURPOSE: To evaluate bimanual microincision cataract surgery (MICS) clear corneal incision (CCI) architectural features over the long-term using anterior segment optical coherence tomography (AS-OCT).
DESIGN: Case series.
SETTING: Institute of Ophthalmology, University of Modena, Modena, Italy.
METHODS: Patients who had uneventful bimanual MICS in the previous 2 to 16 months were examined using AS-OCT. Images were used to measure corneal thickness, incision length, incision angle, incidence of epithelial or endothelial gaping, misalignment, Descemet membrane detachment, and posterior wound retraction.
RESULTS: Fifty-two eyes (33 patients) were enrolled. Mean incision length and incision angle were, respectively, 1427.91 μm and 31.19 degrees for the right hand, 1440.63 μm and 31.54 degrees for the left hand, 1474.13 μm and 31.27 degrees for temporal incisions, and 1394.41 μm and 31.46 degrees for nasal CCIs. Posterior wound retraction was the only architectural feature found. Its prevalence was 7.10% at 2 to 3 months, 31.8% at 4 to 11 months, and 33.3% at 12 months. Fifty-three percent of posterior wound retractions were in 1.8 mm CCIs and 47% in 1.4 mm CCIs.
CONCLUSIONS: Bimanual MICS was not related to particular morphologic features of CCIs. The enlargement of 1 incision or construction of the incision with the dominant or the nondominant hand did not affect long-term wound architecture. Posterior wound retraction was the only architectural feature; however, its prevalence seems substantially lower than with other surgical techniques.
Copyright © 2012 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22921232     DOI: 10.1016/j.jcrs.2012.05.044

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  6 in total

1.  Bimanual microincision cataract surgery with implantation of the new Incise® MJ14 intraocular lens through a 1.4 mm incision.

Authors:  Gian Maria Cavallini; Tommaso Verdina; Michele De Maria; Elisa Fornasari; Giulio Torlai; Veronica Volante; Simone Donati; Carlo Cagini
Journal:  Int J Ophthalmol       Date:  2017-11-18       Impact factor: 1.779

2.  Structural analysis of different incision sizes and stromal hydration in cataract surgery using anterior segment optical coherence tomography.

Authors:  Jong-Wook Bang; Jong-Hyun Lee; Jin-Hyoung Kim; Do-Hyung Lee
Journal:  Korean J Ophthalmol       Date:  2015-01-22

3.  Long-term follow-up for bimanual microincision cataract surgery: comparison of results obtained by surgeons in training and experienced surgeons.

Authors:  Gian Maria Cavallini; Tommaso Verdina; Matteo Forlini; Veronica Volante; Michele De Maria; Giulio Torlai; Caterina Benatti; Giancarlo Delvecchio
Journal:  Clin Ophthalmol       Date:  2016-05-26

4.  Bimanual Microincision Cataract Surgery versus Coaxial Microincision Cataract Surgery: A Meta-Analysis of Randomized Controlled Trials and Cohort Studies.

Authors:  Chenxi Fu; Naipin Chu; Xiaoning Yu; Ke Yao
Journal:  J Ophthalmol       Date:  2017-08-23       Impact factor: 1.909

5.  Clinical results after microincision biaxial cataract surgery and implantation of an Incise intraocular lens.

Authors:  Wojciech Lubiński; Marta Kirkiewicz; Karolina Podborączyńska-Jodko
Journal:  Int Ophthalmol       Date:  2017-08-12       Impact factor: 2.031

6.  Intracameral air injection after completion of phacoemulsification cataract surgery: Evaluation of corneal incisions with optical coherence tomography.

Authors:  Erdem Yuksel; Mehmet Ozgur Cubuk; Kubra Serbest Ceylanoglu
Journal:  J Curr Ophthalmol       Date:  2019-02-13
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.