Literature DB >> 22919104

Does etomidate increase vasopressor requirements in patients needing mechanical ventilation?

Mary Elliot1, Glen Brown, I Fan Kuo.   

Abstract

BACKGROUND: Single-dose etomidate is used as an induction agent for rapid-sequence intubation and is associated with transient adrenal insufficiency. There is ongoing debate as to the clinical consequences of this transient adrenal insufficiency for critically ill patients.
OBJECTIVE: To determine if the use of etomidate is associated with higher requirements for a vasopressor, relative to other induction agents, at a single time point (24 h after administration of the induction agent) in patients needing mechanical ventilation.
METHODS: In this retrospective observational study utilizing electronic health records, a convenience sample of 50 patients who had undergone intubation in the emergency department with etomidate were matched (1:1) with patients who had received other induction agents. Matching was based on primary admitting diagnosis relating to the cause of shock, APACHE II (Acute Physiology and Chronic Health Evaluation II) score, age, and sex. All patients were subsequently admitted to critical care areas for management. As a surrogate marker of hemodynamic instability, the vasopressor dose was recorded 24 h after intubation. Vasopressor doses were converted to norepinephrine equivalents for comparison.
RESULTS: The mean dose of vasopressors, in norepinephrine equivalents, was 4 μg/min(-1) for patients receiving etomidate and 3 μg/min(-1) for the control group (mean difference 0.7 μg min(-1), 95% confidence interval [CI] -1.9 to 3.2 μg min(-1), p = 0.61). Twelve of the patients in the etomidate group and 16 of those in the control group required the use of vasopressors at 24 h following intubation (odds ratio 2.3, 95% CI 0.53 to 13.99, p = 0.34).
CONCLUSIONS: Single-dose etomidate does not adversely affect hemodynamic stability, as measured by the dose of vasopressors required at 24 h after administration.

Entities:  

Keywords:  adrenal insufficiency; critical care; etomidate; mechanical ventilation; vasopressors

Year:  2012        PMID: 22919104      PMCID: PMC3420849          DOI: 10.4212/cjhp.v65i4.1157

Source DB:  PubMed          Journal:  Can J Hosp Pharm        ISSN: 0008-4123


  21 in total

1.  Etomidate: not worth the risk in septic patients.

Authors:  Alfred Sacchetti
Journal:  Ann Emerg Med       Date:  2008-07       Impact factor: 5.721

2.  Clinical controversies: etomidate as an induction agent for endotracheal intubation in patients with sepsis: continue to use etomidate for intubation of patients with septic shock.

Authors:  Ron M Walls; Michael F Murphy
Journal:  Ann Emerg Med       Date:  2008-07       Impact factor: 5.721

Review 3.  The effect of a bolus dose of etomidate on cortisol levels, mortality, and health services utilization: a systematic review.

Authors:  Corinne M Hohl; Carolyn H Kelly-Smith; Titus C Yeung; David D Sweet; Mary M Doyle-Waters; Michael Schulzer
Journal:  Ann Emerg Med       Date:  2010-03-25       Impact factor: 5.721

Review 4.  Dobutamine: ten years later.

Authors:  T C Majerus; J F Dasta; J L Bauman; L H Danziger; R R Ruffolo
Journal:  Pharmacotherapy       Date:  1989       Impact factor: 4.705

5.  Effect of induction of anaesthesia with etomidate on corticosteroid synthesis in man.

Authors:  D J Duthie; R Fraser; W S Nimmo
Journal:  Br J Anaesth       Date:  1985-02       Impact factor: 9.166

6.  A comparison of the effects of etomidate and midazolam on hospital length of stay in patients with suspected sepsis: a prospective, randomized study.

Authors:  Karis L Tekwani; Hannah F Watts; Rolla T Sweis; Kathleen H Rzechula; Erik B Kulstad
Journal:  Ann Emerg Med       Date:  2010-09-15       Impact factor: 5.721

7.  Rapid sequence induction in the emergency department: induction drug and outcome of patients admitted to the intensive care unit.

Authors:  C R W Baird; A W Hay; D W McKeown; D C Ray
Journal:  Emerg Med J       Date:  2009-08       Impact factor: 2.740

8.  Duration of adrenal inhibition following a single dose of etomidate in critically ill patients.

Authors:  Marc Vinclair; Christophe Broux; Patrice Faure; Julien Brun; Céline Genty; Claude Jacquot; Olivier Chabre; Jean-François Payen
Journal:  Intensive Care Med       Date:  2007-12-18       Impact factor: 17.440

9.  The effects of etomidate on adrenal responsiveness and mortality in patients with septic shock.

Authors:  Brian H Cuthbertson; Charles L Sprung; Djillali Annane; Sylvie Chevret; Mark Garfield; Serge Goodman; Pierre-Francois Laterre; Jean Louis Vincent; Klaus Freivogel; Konrad Reinhart; Mervyn Singer; Didier Payen; Yoram G Weiss
Journal:  Intensive Care Med       Date:  2009-08-04       Impact factor: 17.440

10.  The incidence of relative adrenal insufficiency in patients with septic shock after the administration of etomidate.

Authors:  Zulfiqar Mohammad; Bekele Afessa; Javier D Finkielman
Journal:  Crit Care       Date:  2006       Impact factor: 9.097

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.