Literature DB >> 22918013

Comparison of metal ion release from different bracket archwire combinations: an in vitro study.

Srinivas Kumar Karnam1, A Naveen Reddy, C M Manjith.   

Abstract

AIM: The metal ion released from the orthodontic appliance may cause allergic reactions particularly nickel and chromium ions. Hence, this study was undertaken to determine the amount of nickel, chromium, copper, cobalt and iron ions released from simulated orthodontic appliance made of new archwires and brackets.
MATERIALS AND METHODS: Sixty sets of new archwire, band material, brackets and ligature wires were prepared simulating fixed orthodontic appliance. These sets were divided into four groups of fifteen samples each. Group 1: Stainless steel rectangular archwires. Group 2: Rectangular NiTi archwires. Group 3: Rectangular copper NiTi archwires. Group 4: Rectangular elgiloy archwires. These appliances were immersed in 50 ml of artificial saliva solution and stored in polypropylene bottles in the incubator to simulate oral conditions. After 90 days the solution were tested for nickel, chromium, copper, cobalt and iron ions using atomic absorption spectrophotometer.
RESULTS: Results showed that high levels of nickel ions were released from all four groups, compared to all other ions, followed by release of iron ion levels. There is no significant difference in the levels of all metal ions released in the different groups.
CONCLUSION: The study confirms that the use of newer brackets and newer archwires confirms the negligible release of metal ions from the orthodontic appliance. CLINICAL SIGNIFICANCE: The measurable amount of metals, released from orthodontic appliances in artificial saliva, was significantly below the average dietary intake and did not reach toxic concentrations.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22918013     DOI: 10.5005/jp-journals-10024-1154

Source DB:  PubMed          Journal:  J Contemp Dent Pract        ISSN: 1526-3711


  3 in total

1.  Influence of Conventional or Invisalign Orthodontic Treatment on Mineral and Trace Element Salivary Levels: Longitudinal Study with Total Reflection X-ray Fluorescence.

Authors:  Aline Campos Zeffa; Bianca Gonçalves Dias; Daiane Cristina Mendonça Santos Silva; Luiz Orbolato Rotta; Eduardo Inocente Jussiani; Avacir Casanova Andrello; Solange de Paula Ramos
Journal:  Biol Trace Elem Res       Date:  2020-09-18       Impact factor: 3.738

2.  The release of metal ions from orthodontic appliances animal tests.

Authors:  Marcin Mikulewicz; Paulina Wołowiec; Maciej Janeczek; Thomas Gedrange; Katarzyna Chojnacka
Journal:  Angle Orthod       Date:  2014-01-13       Impact factor: 2.079

3.  Evaluation of the Corrosion of Five Different Bracket-Archwire Combination: An In-vitro Analysis Using Inductively Coupled Plasma Mass Spectrometry.

Authors:  Zeinab Behroozi; Shahla Momeni Danaei; Ali Reza Sardarian; Vahid Moshkelghosha; Ahmad Reza Sardarian
Journal:  J Dent (Shiraz)       Date:  2016-09
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.