Literature DB >> 22917686

The "no-dissection" technique is safe for reoperative aortic valve replacement with a patent left internal thoracic artery graft.

Tsuyoshi Kaneko1, Foeke Nauta, Wernard Borstlap, Siobhan McGurk, James D Rawn, Lawrence H Cohn.   

Abstract

OBJECTIVE: Management of a patent left internal thoracic artery graft during reoperation is controversial. The "no-dissection" technique avoids dissection and clamping of the left internal thoracic artery graft, and myocardial protection is achieved using adjunctive systemic hypothermia and hyperkalemia. We compared the postoperative outcomes after isolated reoperative aortic valve replacement in patients with previous coronary artery bypass grafting with a patent left internal thoracic artery graft using a no-dissection technique with the outcomes of patients with previous coronary artery bypass grafting without a left internal thoracic artery graft.
METHODS: The outcomes were analyzed for patients who underwent isolated reoperative aortic valve replacement with previous coronary artery bypass grafting from January 1, 2002, to June, 30, 2011. Patency of the left internal thoracic artery was confirmed using either coronary angiography or computed tomography angiography. The patent left internal thoracic artery group did not undergo dissection or clamping of the left internal thoracic artery graft, and myocardial protection was obtained using systemic hypothermia and hyperkalemia. The no left internal thoracic artery group underwent isolated aortic valve replacement with previous coronary artery bypass grafting but had no left internal thoracic artery graft.
RESULTS: A total 174 patients were identified for the patent left internal thoracic artery group and 26 for the no left internal thoracic artery group. The perfusion and crossclamp times were similar. No differences were seen between the 2 groups in operative mortality (6.9% vs 7.7%, P = 1.00). The complication rates were similar, and the peak creatine kinase-MB values within 24 hours of surgery were not significantly different between the 2 groups (median, 27.4 vs 29 μ/mL; P = .72).
CONCLUSIONS: Reoperative aortic valve replacement in patients with previous coronary artery bypass grafting and a patent left internal thoracic artery graft can be performed safely without dissection or clamping of the left internal thoracic artery using systemic hyperkalemia and hypothermia. We believe this method prevents unnecessary injury during dissection of the left internal thoracic artery graft.
Copyright © 2012 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22917686     DOI: 10.1016/j.jtcvs.2012.07.057

Source DB:  PubMed          Journal:  J Thorac Cardiovasc Surg        ISSN: 0022-5223            Impact factor:   5.209


  7 in total

1.  Aortic Valve Replacement for Patients with Functioning Internal Mammalian Artery Grafts.

Authors:  Naoki Masaki; Takashi Ogasawara; Shun-Ichi Kawarai; Katsuo Matsuki
Journal:  Ann Thorac Cardiovasc Surg       Date:  2017-09-26       Impact factor: 1.520

Review 2.  Minimally invasive reoperative aortic valve replacement: a systematic review and meta-analysis.

Authors:  Kevin Phan; Jessie J Zhou; Nithya Niranjan; Marco Di Eusanio; Tristan D Yan
Journal:  Ann Cardiothorac Surg       Date:  2015-01

Review 3.  Reoperative aortic valve replacement through upper hemisternotomy.

Authors:  Igor Gosev; Maroun Yammine; Marzia Leacche; Vladimir Ivkovic; Siobhan McGurk; Lawrence H Cohn
Journal:  Ann Cardiothorac Surg       Date:  2015-01

Review 4.  Repeated valve replacement surgery: technical tips and pitfalls.

Authors:  Kazuo Tanemoto; Hiroshi Furukawa
Journal:  Gen Thorac Cardiovasc Surg       Date:  2014-09-19

5.  A right thoracotomy approach for mitral and tricuspid valve surgery in patients with previous standard sternotomy: comparison with a re-sternotomy approach.

Authors:  Takashi Miura; Kazuyoshi Tanigawa; Seiji Matsukuma; Ichiro Matsumaru; Kazuki Hisatomi; Shiro Hazama; Akira Tsuneto; Kiyoyuki Eishi
Journal:  Gen Thorac Cardiovasc Surg       Date:  2016-03-11

Review 6.  Reoperative minimal access aortic valve replacement.

Authors:  Tsuyoshi Kaneko; Marzia Leacche; John Byrne; Lawrence Cohn
Journal:  J Thorac Dis       Date:  2013-11       Impact factor: 2.895

7.  Heart Valve Surgery in Patients with Patent Coronary Artery Bypass Grafts.

Authors:  Yoshio Misawa; Yasuo Shindo
Journal:  Ann Thorac Cardiovasc Surg       Date:  2018-03-07       Impact factor: 1.520

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.