BACKGROUND: Polymethylmethacrylate (PMMA) cement-augmented dynamic hip screws (DHS) have been used as a solution in unstable intertrochanteric fractures (ITF). Our aim was to investigate the complications in PMMA cement-augmented DHS. METHODS: All patients who had received DHS plate osteosynthesis with or without PMMA cement augmentation from August 2005 to July 2009 in one medical center were retrospectively reviewed. The fractures were classified as unstable (31-A2.2, 31-A2.3 and 31-A3) on the basis of the Arbeitsgemeinschaft für Osteosynthesefragen classification. Inclusion criteria were patients older than 75 years, unstable ITF treated with cement-augmented DHS, and a minimum of 12 months of follow-up. Exclusion criteria were stable ITFs, incomplete chart records and imaging studies, loss to follow-up or death before bone union. RESULTS: Three hundred twenty-one patients received DHS during the study period. Sixty-seven patients were included in the study (25 men and 42 women; mean age, 81.2 years). The mean follow-up time was 40.2 months, and the mean union time was 18.5 weeks (12-40 weeks). No patient had a lag screw cut-out. Six patients had delayed union or nonunion with side plate failures, including side plate breakage in 1 patient, screw breakage in 3, screw pullout in 1, and recurrent side plate breakage and screw breakage in 1. Deep infection occurred in 1 patient, and 1 had osteonecrosis at the femoral head. The procedure-related complication rate was 8.9%. CONCLUSIONS: Cement-augmented DHS have a different failure mode than screw cutout in conventional DHS. Failures tended to be more related to delayed union, nonunion and resultant side plate construct failure.
BACKGROUND:Polymethylmethacrylate (PMMA) cement-augmented dynamic hip screws (DHS) have been used as a solution in unstable intertrochanteric fractures (ITF). Our aim was to investigate the complications in PMMA cement-augmented DHS. METHODS: All patients who had received DHS plate osteosynthesis with or without PMMA cement augmentation from August 2005 to July 2009 in one medical center were retrospectively reviewed. The fractures were classified as unstable (31-A2.2, 31-A2.3 and 31-A3) on the basis of the Arbeitsgemeinschaft für Osteosynthesefragen classification. Inclusion criteria were patients older than 75 years, unstable ITF treated with cement-augmented DHS, and a minimum of 12 months of follow-up. Exclusion criteria were stable ITFs, incomplete chart records and imaging studies, loss to follow-up or death before bone union. RESULTS: Three hundred twenty-one patients received DHS during the study period. Sixty-seven patients were included in the study (25 men and 42 women; mean age, 81.2 years). The mean follow-up time was 40.2 months, and the mean union time was 18.5 weeks (12-40 weeks). No patient had a lag screw cut-out. Six patients had delayed union or nonunion with side plate failures, including side plate breakage in 1 patient, screw breakage in 3, screw pullout in 1, and recurrent side plate breakage and screw breakage in 1. Deep infection occurred in 1 patient, and 1 had osteonecrosis at the femoral head. The procedure-related complication rate was 8.9%. CONCLUSIONS: Cement-augmented DHS have a different failure mode than screw cutout in conventional DHS. Failures tended to be more related to delayed union, nonunion and resultant side plate construct failure.
Authors: L Henry Goodnough; Harsh Wadhwa; Seth S Tigchelaar; Malcolm R DeBaun; Michael J Chen; Matt L Graves; Michael J Gardner Journal: Arch Orthop Trauma Surg Date: 2021-04-07 Impact factor: 2.928
Authors: Hanjo Neumann; Stefan Breer; Nils Reimers; Richard Kasch; Arndt-Peter Schulz; Benjamin Kienast Journal: J Orthop Surg Res Date: 2015-01-28 Impact factor: 2.359
Authors: Deepak Bushan Raina; Vetra Markevičiūtė; Mindaugas Stravinskas; Joeri Kok; Ida Jacobson; Yang Liu; Erdem Aras Sezgin; Hanna Isaksson; Stefan Zwingenberger; Magnus Tägil; Šarūnas Tarasevičius; Lars Lidgren Journal: Front Bioeng Biotechnol Date: 2022-03-02