Abstract

BACKGROUND: Polymethylmethacrylate (PMMA) cement-augmented dynamic hip screws (DHS) have been used as a solution in unstable intertrochanteric fractures (ITF). Our aim was to investigate the complications in PMMA cement-augmented DHS.
METHODS: All patients who had received DHS plate osteosynthesis with or without PMMA cement augmentation from August 2005 to July 2009 in one medical center were retrospectively reviewed. The fractures were classified as unstable (31-A2.2, 31-A2.3 and 31-A3) on the basis of the Arbeitsgemeinschaft für Osteosynthesefragen classification. Inclusion criteria were patients older than 75 years, unstable ITF treated with cement-augmented DHS, and a minimum of 12 months of follow-up. Exclusion criteria were stable ITFs, incomplete chart records and imaging studies, loss to follow-up or death before bone union.
RESULTS: Three hundred twenty-one patients received DHS during the study period. Sixty-seven patients were included in the study (25 men and 42 women; mean age, 81.2 years). The mean follow-up time was 40.2 months, and the mean union time was 18.5 weeks (12-40 weeks). No patient had a lag screw cut-out. Six patients had delayed union or nonunion with side plate failures, including side plate breakage in 1 patient, screw breakage in 3, screw pullout in 1, and recurrent side plate breakage and screw breakage in 1. Deep infection occurred in 1 patient, and 1 had osteonecrosis at the femoral head. The procedure-related complication rate was 8.9%.
CONCLUSIONS: Cement-augmented DHS have a different failure mode than screw cutout in conventional DHS. Failures tended to be more related to delayed union, nonunion and resultant side plate construct failure.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22913862     DOI: 10.4103/2319-4170.106135

Source DB:  PubMed          Journal:  Chang Gung Med J        ISSN: 2072-0939


  8 in total

1.  Indications for cement augmentation in fixation of geriatric intertrochanteric femur fractures: a systematic review of evidence.

Authors:  L Henry Goodnough; Harsh Wadhwa; Seth S Tigchelaar; Malcolm R DeBaun; Michael J Chen; Matt L Graves; Michael J Gardner
Journal:  Arch Orthop Trauma Surg       Date:  2021-04-07       Impact factor: 2.928

2.  Osteosynthesis-screw augmentation by ultrasound-activated biopolymer--an ovine in vivo study assessing biocompatibility and bone-to-implant contact.

Authors:  Hanjo Neumann; Stefan Breer; Nils Reimers; Richard Kasch; Arndt-Peter Schulz; Benjamin Kienast
Journal:  J Orthop Surg Res       Date:  2015-01-28       Impact factor: 2.359

3.  Measurement of Tip Apex Distance and Migration of Lag Screws and Novel Blade Screw Used for the Fixation of Intertrochanteric Fractures.

Authors:  Jesse Chieh-Szu Yang; Hsin-Chang Chen; Yu-Shu Lai; Cheng-Kung Cheng
Journal:  PLoS One       Date:  2017-01-13       Impact factor: 3.240

4.  Cement Augmentation of Dynamic Hip Screw to Prevent Screw Cut Out in Osteoporotic Patients with Intertrochanteric Fractures: A Case Series.

Authors:  Avinash Kumar Rai; Rajesh Goel; Chirag Bhatia; Sumer Singh; Srikiran Thalanki; Ashwin Gondane
Journal:  Hip Pelvis       Date:  2018-12-06

5.  Factors affect stability of intertrochanteric fractures when elderly patients fall.

Authors:  Po-Han Chen; Chi-Chuan Wu; Wen-Jer Chen
Journal:  Biomed J       Date:  2016-03-25       Impact factor: 4.910

6.  A New Augmentation Method for Improved Screw Fixation in Fragile Bone.

Authors:  Deepak Bushan Raina; Vetra Markevičiūtė; Mindaugas Stravinskas; Joeri Kok; Ida Jacobson; Yang Liu; Erdem Aras Sezgin; Hanna Isaksson; Stefan Zwingenberger; Magnus Tägil; Šarūnas Tarasevičius; Lars Lidgren
Journal:  Front Bioeng Biotechnol       Date:  2022-03-02

7.  The effects of bone-substitute augmentation on treatment of osteoporotic intertrochanteric fractures.

Authors:  Fu-Chun Chang; Pao-Yao Chuang; Ching-Yu Lee; Chien-Yin Lee; Ying-Chao Chou; Tsan-Wen Huang; Kuo-Chin Huang; Hsin-Nung Shih; Mel S Lee
Journal:  Biomed J       Date:  2020-05-23       Impact factor: 7.892

8.  Limited Dynamic Hip Screw for Treatment of Intertrochanteric Fractures: A Biomechanical Study.

Authors:  Chunlei Zhang; Bin Zhang; Qirong Dong; Dawei Ge
Journal:  Med Sci Monit       Date:  2018-03-26
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.