Literature DB >> 22913756

Upper urinary tract laparoendoscopic single-site surgery based on a novel cost-effective reusable platform.

Christian Schwentner1, Tilman Todenhöfer, Joerg Seibold, Saladin H Alloussi, Stefan Aufderklamm, Johannes Mischinger, Miriam Germann, Arnulf Stenzl, Georgios Gakis.   

Abstract

BACKGROUND AND
PURPOSE: Several disposable platforms have been introduced for laparoendoscopic single-site (LESS) surgery. Besides technical issues, cost is one of the main limiting factors for their widespread use. We present our experience with LESS surgery for kidney pathologies using the first completely reusable LESS platform. PATIENTS AND METHODS: We performed LESS kidney procedures in 29 patients including nephrectomy (18), partial nephrectomy (3), pyeloplasty (4), and renal cyst ablation (4). All procedures were performed using a completely reusable single-port device (X-Cone) with a simplified combination of standard and prebent instruments. We obtained perioperative and demographic data including a visual analog pain scale (VAS); complications were recorded using Clavien grading.
RESULTS: Mean patient age was 49.31 years. Conversion to standard laparoscopy was necessary in one and addition of a needlescopic instrument in four cases. No open conversion was necessary. Intra- and postoperative complications occurred in two (Clavien II) cases. Mean operative time was 110, 90, and 89 minutes, and hospital stay was 4.9, 3.1, and 3.6 days for nephrectomy, partial nephrectomy, and pyeloplasty, respectively. Mean VAS was 2.13, 1.67, and 1.5 while blood loss was 81.3 mL, 140 mL, and 17.5 mL, respectively. There were no positive resection margins.
CONCLUSIONS: LESS with a completely reusable platform is feasible for different upper urinary tract procedures yielding favorable functional and cosmetic results. A simplified combination of standard straight instruments and a single prebent grasper facilitates handling and shortens the learning curve. Reusable materials significantly reduce cost and may help to further adopt LESS surgery in surgical practice.

Entities:  

Mesh:

Year:  2012        PMID: 22913756     DOI: 10.1089/end.2012.0409

Source DB:  PubMed          Journal:  J Endourol        ISSN: 0892-7790            Impact factor:   2.942


  3 in total

Review 1.  Laparoendoscopic single-site surgery in kidney surgery: clinical experience and future perspectives.

Authors:  Panagiotis Kallidonis; Stavros Kontogiannis; Iason Kyriazis; Ioannis Georgiopoulos; Abdulrahman Al-Aown; Jens-Uwe Stolzenburg; Evangelos Liatsikos
Journal:  Curr Urol Rep       Date:  2013-10       Impact factor: 3.092

2.  Laparoendoscopic single-site (LESS) varicocelectomy with reusable components: comparison with the conventional laparoscopic technique.

Authors:  Frank Friedersdorff; Seven Johannes Aghdassi; Peter Werthemann; Hannes Cash; Irena Goranova; Jonas Felix Busch; Jan Ebbing; Stefan Hinz; Kurt Miller; Joerg Neymeyer; Tom Florian Fuller
Journal:  Surg Endosc       Date:  2013-04-03       Impact factor: 4.584

3.  Retroperitoneal laparoendoscopic single-site approach for renal cyst decortication - first experience and a review of literature.

Authors:  Nicolae Crisan; Iulia Andras; Teodora Telecan; Andreea Szabo; Andrei Popa; Radu-Tudor Coman; Paul Medan; Ioan Coman
Journal:  Clujul Med       Date:  2018-07-31
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.