Literature DB >> 22913388

Ultrasensitive multianalyte electrochemical immunoassay based on metal ion functionalized titanium phosphate nanospheres.

Li-Na Feng1, Zhi-Ping Bian, Juan Peng, Fang Jiang, Guo-Hai Yang, Ying-Di Zhu, Di Yang, Li-Ping Jiang, Jun-Jie Zhu.   

Abstract

A novel multianalyte electrochemical immunoassay was developed for ultrasensitive detection of human cardiopathy biomarkers cardiac troponin I (cTnI) and human heart-type fatty-acid-binding protein (FABP) using metal ion functionalized titanium phosphate nanospheres (TiP-metal ion) as labels. The metal ions could be detected directly through square wave voltammetry (SWV) without metal preconcentration, and the distinct voltammetric peaks had a close relationship with each sandwich-type immunoreaction. The position and size of the peaks reflected the identity and level of the corresponding antigen. The large amount of metal ions loading on the TiP nanospheres greatly amplified the detection signals, and the good biocompatibility of graphene nanoribbons (GONRs) retained good stability for the sandwich-type immunoassay. The proposed immunoassay exhibited high sensitivity and selectivity for the detection of cTnI and FABP. The linear relationships between electrochemical signals and the concentrations of cTnI and FABP were obtained in the range of 0.05 pg/mL-50 ng/mL and 0.05 pg/mL-50 ng/mL, respectively. The detection limits of cTnI and HIgG were 1 and 3 fg/mL (S/N = 3), respectively. Moreover, the immunoassay accurately detected the concentrations of cTnI and FABP in human serum samples, which were demonstrated to have excellent correlations with the standard enzyme linked immunosorbent assay (ELISA) method. The results suggested that the electrochemical immunoassay would be promising in the point-of-care diagnostics application of clinical screening of acute myocardial infarction (AMI) biomarkers.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22913388     DOI: 10.1021/ac301438v

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  7 in total

1.  Core-shell heterostructured multiwalled carbon nanotubes@reduced graphene oxide nanoribbons/chitosan, a robust nanobiocomposite for enzymatic biosensing of hydrogen peroxide and nitrite.

Authors:  Veerappan Mani; Mani Govindasamy; Shen-Ming Chen; Tse-Wei Chen; Annamalai Senthil Kumar; Sheng-Tung Huang
Journal:  Sci Rep       Date:  2017-09-19       Impact factor: 4.379

Review 2.  Multiplexed Point-of-Care Testing - xPOCT.

Authors:  Can Dincer; Richard Bruch; André Kling; Petra S Dittrich; Gerald A Urban
Journal:  Trends Biotechnol       Date:  2017-04-26       Impact factor: 19.536

Review 3.  Nanomaterials for Electrochemical Immunosensing.

Authors:  Mingfei Pan; Ying Gu; Yaguang Yun; Min Li; Xincui Jin; Shuo Wang
Journal:  Sensors (Basel)       Date:  2017-05-05       Impact factor: 3.576

Review 4.  Current Trends in Nanomaterial-Based Amperometric Biosensors.

Authors:  Akhtar Hayat; Gaëlle Catanante; Jean Louis Marty
Journal:  Sensors (Basel)       Date:  2014-12-08       Impact factor: 3.576

5.  Sensitive Bioanalysis Based on in-Situ Droplet Anodic Stripping Voltammetric Detection of CdS Quantum Dots Label after Enhanced Cathodic Preconcentration.

Authors:  Xiaoli Qin; Linchun Wang; Qingji Xie
Journal:  Sensors (Basel)       Date:  2016-08-23       Impact factor: 3.576

Review 6.  Electrochemical sensing of blood proteins for mild traumatic brain injury (mTBI) diagnostics and prognostics: towards a point-of-care application.

Authors:  Nadezda Pankratova; Milica Jović; Marc E Pfeifer
Journal:  RSC Adv       Date:  2021-05-12       Impact factor: 4.036

7.  Towards a Point-of-Care (POC) Diagnostic Platform for the Multiplex Electrochemiluminescent (ECL) Sensing of Mild Traumatic Brain Injury (mTBI) Biomarkers.

Authors:  Milica Jović; Denis Prim; Edis Saini; Marc Emil Pfeifer
Journal:  Biosensors (Basel)       Date:  2022-03-11
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.