A self-normalization reconstruction technique for PET scans using the positron emission data.

André Salomon1, Benjamin Goldschmidt, René Botnar, Fabian Kiessling, Volkmar Schulz.   

Abstract

Positron emission tomography (PET) image quality in both clinical and preclinical environments highly depends on an accurate knowledge of the detector hardware to correct for image quality degrading effects like gain, temperature, and photon detection efficiency variations of the individual crystals. In conventional PET systems some of these variations are typically corrected using a dedicated calibration scan in which the scanner performance for a well-known activity source is measured. We propose an alternative method for estimating the relative sensitivity of each detector pixel using the coincidences as well as the singles emission data of each PET scan. The overall idea is to compare the total sum of all measured single photons before coincidence processing in each crystal with a steadily low-frequent distribution that can normally be expected. Both the estimated activity and the estimated detector sensitivity are simultaneously improved by using an extended iterative reconstruction scheme. This way we ensure the use of an optimal calibration correction (with the exception of a global factor) for each data set, even if the scanner performance has changed between two scans. Data measured with a preclinical PET scanner (HYPERIon-I) which uses analog silicon photomultipliers in combination with a custom-made ASIC shows a significant increase of image quality and homogeneity using the proposed method.

Entities:  

Mesh:

Year:  2012        PMID: 22910096     DOI: 10.1109/TMI.2012.2213827

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  4 in total

1.  Estimation of Crystal Timing Properties and Efficiencies for the Improvement of (Joint) Maximum-Likelihood Reconstructions in TOF-PET.

Authors:  Ahmadreza Rezaei; Georg Schramm; Koen Van Laere; Johan Nuyts
Journal:  IEEE Trans Med Imaging       Date:  2019-08-28       Impact factor: 10.048

2.  Simultaneous PET/MR imaging with a radio frequency-penetrable PET insert.

Authors:  Alexander M Grant; Brian J Lee; Chen-Ming Chang; Craig S Levin
Journal:  Med Phys       Date:  2017-01       Impact factor: 4.071

3.  Initial PET performance evaluation of a preclinical insert for PET/MRI with digital SiPM technology.

Authors:  David Schug; Christoph Lerche; Bjoern Weissler; Pierre Gebhardt; Benjamin Goldschmidt; Jakob Wehner; Peter Michael Dueppenbecker; Andre Salomon; Patrick Hallen; Fabian Kiessling; Volkmar Schulz
Journal:  Phys Med Biol       Date:  2016-03-17       Impact factor: 3.609

4.  Comments on the NEMA NU 4-2008 Standard on Performance Measurement of Small Animal Positron Emission Tomographs.

Authors:  Patrick Hallen; David Schug; Volkmar Schulz
Journal:  EJNMMI Phys       Date:  2020-02-24
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.