Literature DB >> 22910084

Pulsatile vs. continuous flow in ventricular assist device therapy.

Gabriel Loor1, Gonzalo Gonzalez-Stawinski.   

Abstract

A left ventricular assist device (LVAD) is an important treatment option for a patient with end-stage heart failure. Both continuous and non-pulsatile devices are available, each with different effects on a patient's physiology. In general, these effects are not clinically significant with the exception of bleeding events which are more common with continuous-flow devices in some series. Both devices increase survival beyond medical management. Continuous-flow devices are smaller and are associated with less overall morbidity than pulsatile devices.
Copyright © 2012. Published by Elsevier Ltd.

Entities:  

Mesh:

Year:  2012        PMID: 22910084     DOI: 10.1016/j.bpa.2012.03.004

Source DB:  PubMed          Journal:  Best Pract Res Clin Anaesthesiol        ISSN: 1521-6896


  12 in total

1.  Shear stress and blood trauma under constant and pulse-modulated speed CF-VAD operations: CFD analysis of the HVAD.

Authors:  Zengsheng Chen; Sofen K Jena; Guruprasad A Giridharan; Michael A Sobieski; Steven C Koenig; Mark S Slaughter; Bartley P Griffith; Zhongjun J Wu
Journal:  Med Biol Eng Comput       Date:  2018-11-08       Impact factor: 2.602

2.  Gastric antral vascular ectasia: a rare manifestation for gastrointestinal bleeding in left ventricular assist device patients--an initial report.

Authors:  Basem Alkurdi; Klaus Monkemuller; Ali S Khan; Leona Council; Brendan M McGuire; Shajan Peter
Journal:  Dig Dis Sci       Date:  2014-05-13       Impact factor: 3.199

Review 3.  Gastrointestinal Bleeding Following LVAD Placement from Top to Bottom.

Authors:  Kelly Cushing; Vladimir Kushnir
Journal:  Dig Dis Sci       Date:  2016-03-26       Impact factor: 3.199

4.  Gastrointestinal bleeding in a patient with a continuous-flow biventricular assist device.

Authors:  Raymond V Mirasol; Jason J Tholany; Hasini Reddy; Billie S Fyfe-Kirschner; Christina L Cheng; Issam F Moubarak; John L Nosher
Journal:  World J Radiol       Date:  2016-04-28

5.  Shear-induced platelet receptor shedding by non-physiological high shear stress with short exposure time: glycoprotein Ibα and glycoprotein VI.

Authors:  Zengsheng Chen; Nandan K Mondal; Jun Ding; Jingya Gao; Bartley P Griffith; Zhongjun J Wu
Journal:  Thromb Res       Date:  2015-02-07       Impact factor: 3.944

6.  Video capsule endoscopy in left ventricular assist device recipients with obscure gastrointestinal bleeding.

Authors:  Surachai Amornsawadwattana; Michael Nassif; David Raymer; Shane LaRue; Chien-Huan Chen
Journal:  World J Gastroenterol       Date:  2016-05-14       Impact factor: 5.742

7.  Pulse pressure-dependent cerebrovascular eNOS regulation in mice.

Authors:  Adeline Raignault; Virginie Bolduc; Frédéric Lesage; Eric Thorin
Journal:  J Cereb Blood Flow Metab       Date:  2016-07-21       Impact factor: 6.200

8.  Octreotide for the Management of Gastrointestinal Bleeding in a Patient with a HeartWare Left Ventricular Assist Device.

Authors:  Geetanjali Dang; Ryan Grayburn; Geoffrey Lamb; Adrian Umpierrez De Reguero; Nunzio Gaglianello
Journal:  Case Rep Cardiol       Date:  2014-12-18

Review 9.  Clinical Approach to Manage Gastrointestinal Bleeding with a Left Ventricular Assist Device (LVAD).

Authors:  Irfan Ahsan; Aniqa Faraz; Asif Mehmood; Waqas Ullah; Ali R Ghani
Journal:  Cureus       Date:  2019-12-10

10.  Efficacy of Pulsatile Flow Perfusion in Adult Cardiac Surgery: Hemodynamic Energy and Vascular Reactivity.

Authors:  Mikhail Dodonov; Francesco Onorati; Giovanni Battista Luciani; Alessandra Francica; Maddalena Tessari; Tiziano Menon; Leonardo Gottin; Aldo Domenico Milano; Giuseppe Faggian
Journal:  J Clin Med       Date:  2021-12-17       Impact factor: 4.241

View more