Literature DB >> 22907959

Analysis and design of RF power and data link using amplitude modulation of Class-E for a novel bone conduction implant.

Hamidreza Taghavi1, Bo Håkansson, Sabine Reinfeldt.   

Abstract

This paper presents analysis and design of a radio frequency power and data link for a novel Bone Conduction Implant (BCI) system. Patients with conductive and mixed hearing loss and single-sided deafness can be rehabilitated by bone-anchored hearing aids (BAHA). Whereas the conventional hearing aids transmit sound to the tympanic membrane via air conduction, the BAHA transmits sound via vibrations through the skull directly to the cochlea. It uses a titanium screw that penetrates the skin and needs life-long daily care; it may cause skin infection and redness. The BCI is developed as an alternative to the percutaneous BAHA since it leaves the skin intact. The BCI comprises an external audio processor with a transmitter coil and an implanted unit called the bridging bone conductor with a receiver coil. Using amplitude modulation of the Class-E power amplifier that drives the inductive link, the sound signal is transmitted to the implant through the intact skin. It was found that the BCI can generate enough output force level for candidate patients. Maximum power output of the BCI was designed to occur at 5-mm skin thickness and the variability was within 1.5 dB for 1-8-mm skin thickness variations.

Entities:  

Mesh:

Year:  2012        PMID: 22907959     DOI: 10.1109/TBME.2012.2213252

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  4 in total

1.  The bone conduction implant: Clinical results of the first six patients.

Authors:  Sabine Reinfeldt; Bo Håkansson; Hamidreza Taghavi; Karl-Johan Fredén Jansson; Måns Eeg-Olofsson
Journal:  Int J Audiol       Date:  2015-02-23       Impact factor: 2.117

Review 2.  New developments in bone-conduction hearing implants: a review.

Authors:  Sabine Reinfeldt; Bo Håkansson; Hamidreza Taghavi; Måns Eeg-Olofsson
Journal:  Med Devices (Auckl)       Date:  2015-01-16

3.  Robustness and lifetime of the bone conduction implant - a pilot study.

Authors:  Karl-Johan Fredén Jansson; Bo Håkansson; Cristina Rigato; Måns Eeg-Olofsson; Sabine Reinfeldt
Journal:  Med Devices (Auckl)       Date:  2019-02-26

4.  A New Type of Wireless Transmission Based on Digital Direct Modulation for Use in Partially Implantable Hearing Aids.

Authors:  Jong-Hoon Kim; Jin-Ho Cho; Ki-Woong Seong; Myoung-Nam Kim
Journal:  Sensors (Basel)       Date:  2021-04-16       Impact factor: 3.576