Literature DB >> 22907131

Airborne fungi and bacteria in child daycare centers and the effectiveness of weak acid hypochlorous water on controlling microbes.

Nai-Tzu Chen1, Yu-Min Su, Nai-Yun Hsu, Pei-Chih Wu, Huey-Jen Su.   

Abstract

A three-week-long biological sampling scheme was conducted in two child daycare centers (CDCCs) in order to investigate interdiurnal and diurnal variations in indoor airborne microbes as well as the efficiency of weak acid hypochlorous water (WAHW) on disinfecting indoor microbes. During the second week of sampling, WAHW was sprayed using a fogger in the classroom after children had left and before they returned the next morning. An identical cycle of experiments was performed twice in the winter and spring. Without WAHW intervention, the respective mean of the indoor concentrations and I/O ratios were 8732-47581 CFU m(-3) and 0.96-2.53 for fungi, and 6706-28998 CFU m(-3) and 1.10-11.92 for bacteria, showing severe bio-contamination in the CDCCs. Moreover, a relatively high level of bacterial pollution was found at noon, whereas a greater fungal pollution could be detected in the morning and at noon. Among five school days, the fungal and bacterial pollution may be higher on Monday and on Wednesday, Thursday, and Friday, respectively. Furthermore, with WAHW intervention, the indoor microbial concentrations and I/O ratios were decreased significantly. The reduction of I/O ratios caused by WAHW disinfection was accomplished in the morning for bacteria and in the morning, at noon, and in the afternoon for fungi. In conclusion, this study clearly clarified the risky period during which children may be exposed to hazardous environments, and demonstrated the effectiveness of spraying WAHW the night before on decontaminating indoor airborne microbes on the following day, especially in the case of fungi.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22907131     DOI: 10.1039/c2em30113j

Source DB:  PubMed          Journal:  J Environ Monit        ISSN: 1464-0325


  2 in total

1.  Metagenomic insights into the bioaerosols in the indoor and outdoor environments of childcare facilities.

Authors:  Su-Kyoung Shin; Jinman Kim; Sung-min Ha; Hyun-Seok Oh; Jongsik Chun; Jongryeul Sohn; Hana Yi
Journal:  PLoS One       Date:  2015-05-28       Impact factor: 3.240

2.  Inactivation of an enterovirus by airborne disinfectants.

Authors:  Thomas Thevenin; Pierre-Emmanuel Lobert; Didier Hober
Journal:  BMC Infect Dis       Date:  2013-04-15       Impact factor: 3.090

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.