STUDY
DESIGN: Case-control study.
OBJECTIVE: To verify whether metal ions in the serum of patients bearing spinal stainless steel instrumentation were elevated over the long-term period after implantation of stainless steel prostheses and to determine whether these levels could predict potential unfavorable outcomes. SUMMARY OF BACKGROUND DATA: Instrumented spinal arthrodesis, the standard procedure to correct scoliosis, routinely remains in situ for the lifetime of the patient. Elevated metal ion levels have been reported at short-term follow-up, but the long-term status, possibly related to systemic toxic effects, is unknown.
METHODS: Twenty-two patients treated for scoliosis with posterior spinal arthrodesis using stainless steel instrumentation were included. Minimum follow-up was 10 years. Oswestry Disability Index and visual analog scale were recorded. Chromium (Cr) and nickel (Ni) levels were measured (ng/mL) and compared with levels in a control group including 30 healthy subjects. A receiver-operating characteristic curve was calculated on the basis of the clinical assessment (pain and disability) and the x-ray picture; the cutoff values for the parameters were settled, and the ion-testing potential was considered as a surrogate marker for failure.
RESULTS: The level of Cr was significantly increased in patients, compared with controls (P=0.018). A remarkable Cr release without any clinical-radiologic sign was recorded in some female patients. A high specificity (93%), positive likelihood ratio (7.00), and overall accuracy (77%) were calculated for Cr; these indicate a high risk of failure when the levels exceeded the cutoff value, which was 0.6 ng/mL. No significant difference between the groups was found for Ni (P=0.7).
CONCLUSIONS: Cr testing is suggested as a reliable marker for the malfunctioning assessment and as a support for standard procedures, especially with doubtful diagnosis. Furthermore, high levels of Cr ions were observed in female patients. This finding deserves attention especially when counseling young fertile women.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 22907064     DOI: 10.1097/BSD.0b013e31826eaa27

Source DB:  PubMed          Journal:  J Spinal Disord Tech        ISSN: 1536-0652


  5 in total

1.  Serum metal ion levels in adolescent idiopathic scoliosis (AIS) patients 25 years after treated with Harrington rod instrumentation or bracing.

Authors:  Simon Thorbjørn Sørensen; Anne Vibeke Schmedes; Mikkel Østerheden Andersen; Leah Carreon; Ane Simony
Journal:  Spine Deform       Date:  2021-05-25

2.  Corrosion of Harrington rod in idiopathic scoliosis: long-term effects.

Authors:  Beth Sherman; Tanya Crowell
Journal:  Eur Spine J       Date:  2017-06-17       Impact factor: 3.134

3.  A systematic review of metal ion concentrations following instrumented spinal fusion.

Authors:  Omar Siddiqi; Jennifer C Urquhart; Parham Rasoulinejad
Journal:  Spine Deform       Date:  2020-08-11

4.  Chromium and Nickel Concentrations in Subjects with a Stainless Steel Metal-on-Metal Cervical Disc Arthroplasty: Results from a Prospective Longitudinal Study with 7 Years Follow-Up.

Authors:  Vaneet Singh; Anastasia K Skipor; Abdulhafez A Selim; Joshua J Jacobs
Journal:  Int J Spine Surg       Date:  2018-08-31

5.  Analysis of serum levels of titanium and aluminium ions in patients with early onset scoliosis operated upon using the magnetic growing rod-a single centre study of 14 patients.

Authors:  Mandar Deepak Borde; Sarang Sapare; Emile Schutgens; Chadi Ali; Hilali Noordeen
Journal:  Spine Deform       Date:  2021-07-23
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.