Literature DB >> 22906407

Intraosseous temperature changes during the use of piezosurgical inserts in vitro.

S Schütz1, J Egger, S Kühl, A Filippi, J Th Lambrecht.   

Abstract

This study concerns intraosseous temperature changes during the use of piezosurgical inserts. On six fresh pig jaws heated to body temperature (36°C), osteotomies and osteoplasties were performed in vitro with the Piezosurgery(®) 3 device (Mectron, Carasco, Italy) and various inserts. The intraosseous temperature increases were measured at a depth of 3mm and at a distance of 1mm from the working site using nickel-chromium/nickel temperature sensors. 20°C Ringer's solution was used for cooling in an initial test series and 10°C Ringer's in a second series. The processed bone was examined using digital volume tomography images to determine the ratio of cortical to cancellous bone thickness. Mean temperature increases of 4.4-10.9°C were found; maximum temperature peaks were over 47°C for an average of only 8.5 s. The type of piezosurgical insert had a marked influence on intraosseous temperature generation (p=0.026); the thickness of the cortical bone and the temperature of the coolant did not. Coolant temperature had an influence on the bone cooling time (p=0.013). The results show that correct use of the piezosurgery device does not give rise to prolonged temperature increases over 47°C and hence does not cause any irreversible thermal damage in the bone.
Copyright © 2012 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22906407     DOI: 10.1016/j.ijom.2012.06.007

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Surg        ISSN: 0901-5027            Impact factor:   2.789


  4 in total

1.  Identification of possible factors influencing temperatures elevation during implant site preparation with piezoelectric technique.

Authors:  Luca Lamazza; Domenica Laurito; Marco Lollobrigida; Orlando Brugnoletti; Girolamo Garreffa; Alberto De Biase
Journal:  Ann Stomatol (Roma)       Date:  2015-02-09

2.  LeFort I segmented osteotomy experience with piezosurgery in orthognathic surgery.

Authors:  Sergio Olate; Leandro Pozzer; Alejandro Unibazo; Claudio Huentequeo-Molina; Felipe Martinez; Márcio de Moraes
Journal:  Int J Clin Exp Med       Date:  2014-08-15

3.  Ultrasonic versus conventional gap arthroplasty for the release of ankylosis of temporomandibular joint: a prospective cohort study.

Authors:  Tingting Jia; Li Wang; Youbai Chen; Rui Zhao; Liang Zhu; Lejun Xing; Naman Rao; Jie Zhang; Qixu Zhang; Meredith August; Yan Han; Haizhong Zhang
Journal:  Sci Rep       Date:  2019-01-23       Impact factor: 4.379

Review 4.  Piezoelectric Bone Surgery: A Review of the Literature and Potential Applications in Veterinary Oromaxillofacial Surgery.

Authors:  Philippe Hennet
Journal:  Front Vet Sci       Date:  2015-05-05
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.