Heat and Moisture Exchangers and Humidification Efficacy in Pediatrics: Effects of Ventilator Settings and ETT Leakage.

Alan de Klerk1, Antonio M Esquinas.   

Abstract

Entities:  

Year:  2012        PMID: 22900156      PMCID: PMC3415138          DOI: 10.1155/2012/585280

Source DB:  PubMed          Journal:  Crit Care Res Pract        ISSN: 2090-1305


× No keyword cloud information.
Heat and moisture exchangers (HMEs) have been increasingly used for humidification during mechanical ventilation in pediatric patients [1]. However, efficacy of HMEs in the pediatric population has not yet been fully evaluated and there is limited information in the literature regarding the effects of ventilator settings and endotracheal tube (ETT) leakage on the humidification performance of HMEs. Chikata et al. [2] tested ten pediatric HMEs in a model lung, measuring performance under different respiratory rates, tidal volumes TVs (achieved with different pressure control levels), and leakage conditions. They found that eight of the ten HMEs maintained absolute humidity (AH) at more than 30 mg/L, the minimum level recommended by the American Association for Respiratory Care (AARC). With a small leak, AH decreased below 30 mg/L (26.6 to 29.5 mg/L), decreasing further (19.7 to 27.3 mg/L) with a larger leak. Pressure control (tidal volume) level did not statistically significantly affect AH values, although there was a trend to decreased AH at higher tidal volumes. In three of the HMEs, increased respiratory rate resulted in a significantly higher AH. In six of the other seven HMEs, there was a nonstatistically significant trend to higher AH with increased respiratory rate, with one HME showing a nonsignificant trend to lower AH. We think this is a well-designed and conducted study and provides valuable information regarding the use of HMEs in pediatric patients under different conditions. The effect of ETT leakage on AH is nicely demonstrated and is consistent with previously published data on mechanically ventilated adults. However, we had some questions regarding the study's other findings and their possible explanation as follows the study found that 8 out of 10 pediatric HMEs maintained AH at more than 30 mg/L, while they quote the Luchetti et al. [3] study they reference as showing “AH of less than 28 mg/L in all HMEs used with pediatric patients” despite using similar one-way valve methodology in their circuit to prevent mixing of inspired and expired gases? This finding is even more puzzling given that one of the two HMEs used in the Luchetti study, the Hygroboy (Covidien [formerly Tyco Healthcare], Mirandola, Italy), in the present study was found to produce the highest AH (32.4 mg/L) of the ten HMEs tested. How is this difference in findings between the 2 studies of the same HME explained? the finding that increased respiratory rates resulted in a trend to higher AH that reached significance in 3 of the tested humidifiers is interesting. Previous studies of HMEs in adults and children have found lower AH associated with higher tidal volumes [4, 5] and minute volumes (MVs) [1, 6, 7]. It would seem more logical that an increasing respiratory rate presumably would result in a higher MV, with resultant lower AH, but Chikata et al. found the opposite. The authors did not comment on this in their paper, and we wonder if they have a plausible explanation for this; finally, the authors speculate that the finding of a linear relationship between increasing dead space and increasing AH might possibly be related to improved humidification in those HMEs with larger internal volume and dead space. Since it is generally recommended to minimize dead space with HMEs, in particular in pediatric use, would the authors care to comment on striking a balance between maximizing humidification capacity and minimizing dead space?
  7 in total

Review 1.  Humidification of respired gases in neonates and infants.

Authors:  Holger Schiffmann
Journal:  Respir Care Clin N Am       Date:  2006-06

2.  Evaluation of the efficiency of heat and moisture exchangers during paediatric anaesthesia.

Authors:  M Luchetti; A Pigna; A Gentili; G Marraro
Journal:  Paediatr Anaesth       Date:  1999       Impact factor: 2.556

3.  A novel method of evaluation of three heat-moisture exchangers in six different ventilator settings.

Authors:  N Unal; J K Kanhai; S L Buijk; J C Pompe; W P Holland; I Gültuna; C Ince; B Saygin; H A Bruining
Journal:  Intensive Care Med       Date:  1998-02       Impact factor: 17.440

4.  Comparing two heat and moisture exchangers with one vaporizing humidifier in patients with minute ventilation greater than 10 L/min.

Authors:  C Martin; L Thomachot; B Quinio; X Viviand; J Albanese
Journal:  Chest       Date:  1995-05       Impact factor: 9.410

5.  Performance evaluation of three vaporizing humidifiers and two heat and moisture exchangers in patients with minute ventilation > 10 L/min.

Authors:  C Martin; L Papazian; G Perrin; P Bantz; F Gouin
Journal:  Chest       Date:  1992-11       Impact factor: 9.410

6.  Humidification performance of heat and moisture exchangers for pediatric use.

Authors:  Yusuke Chikata; Chihiro Sumida; Jun Oto; Hideaki Imanaka; Masaji Nishimura
Journal:  Crit Care Res Pract       Date:  2012-01-18

7.  Evaluating humidity recovery efficiency of currently available heat and moisture exchangers: a respiratory system model study.

Authors:  Jeanette Janaina Jaber Lucato; Alexander Bernard Adams; Rogério Souza; Jamili Anbar Torquato; Carlos Roberto Ribeiro Carvalho; John J Marini
Journal:  Clinics (Sao Paulo)       Date:  2009       Impact factor: 2.365