Literature DB >> 22898749

A prospective comparative study between differential moments and miniscrews in anchorage control.

Amirparviz R Davoody1, Laura Posada, Achint Utreja, Nandakumar Janakiraman, William P Neace, Flavio Uribe, Ravindra Nanda.   

Abstract

The purpose of this study was to measure the efficacy of anchorage control between differential moments mechanics and temporary anchorage devices in a clinical trial. Forty-six patients requiring extraction of maxillary first premolars were allocated into 2 treatment groups. The differential moments group (G1) received a nickel titanium (NiTi) intrusion arch and a 150g NiTi closing coil spring for separate canine retraction, followed by a continuous mushroom loop archwire for the retraction of the incisors. The TAD group (G2) received one miniscrew placed between maxillary second premolars and first molars with a 150 g NiTi closing coil spring connecting the miniscrew to a hook placed in the archwire between the lateral incisor and canine. Lateral cephalograms were taken before (T1) and after incisor retraction (T2). The ratio of molar protraction to incisor retraction was calculated and intragroup and intergroup changes in upper lip, maxillary incisor and molar position were analyzed by paired and independent t-tests. Twenty-eight patients were analyzed after 18 patients did not receive the intervention, were lost to follow-up, or discontinued treatment. The ratio of molar protraction to incisor retraction in G1 was 0.44 and in G2 was -0.11, which was significantly different. There was a statistically significant change in upper lip from T1 to T2 but no difference between the two groups. Moreover, there was a significant distal molar tipping and lingual incisor tipping in G2. There is a significant difference in the amount of anchorage control using differential moments mechanics compared to TADs. Although statistically significant retraction of upper lip was observed in both groups, there was no significant difference between the two groups.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22898749     DOI: 10.1093/ejo/cjs046

Source DB:  PubMed          Journal:  Eur J Orthod        ISSN: 0141-5387            Impact factor:   3.075


  8 in total

Review 1.  A Scoping Review about the Characteristics and Success-Failure Rates of Temporary Anchorage Devices in Orthodontics.

Authors:  Daniel Jaramillo-Bedoya; Gustavo Villegas-Giraldo; Andrés A Agudelo-Suárez; Diana Milena Ramírez-Ossa
Journal:  Dent J (Basel)       Date:  2022-05-06

2.  A comparative anchorage control study between conventional and self-ligating bracket systems using differential moments.

Authors:  Marcio Rodrigues de Almeida; Francisco Herrero; Amine Fattal; Amirparviz R Davoody; Ravindra Nanda; Flavio Uribe
Journal:  Angle Orthod       Date:  2013-06-07       Impact factor: 2.079

3.  Effect of piezocision corticotomy on en-masse retraction.

Authors:  Abdulkarim A Hatrom; Khalid H Zawawi; Reem M Al-Ali; Hanadi M Sabban; Talal M Zahid; Ghassan A Al-Turki; Ali H Hassan
Journal:  Angle Orthod       Date:  2020-09-01       Impact factor: 2.079

Review 4.  Effectiveness of en masse versus two-step retraction: a systematic review and meta-analysis.

Authors:  Mumen Z Rizk; Hisham Mohammed; Omar Ismael; David R Bearn
Journal:  Prog Orthod       Date:  2018-01-05       Impact factor: 2.750

Review 5.  Maxillary incisors changes during space closure with conventional and skeletal anchorage methods: a systematic review.

Authors:  Yasas Shri Nalaka Jayaratne; Flavio Uribe; Nandakumar Janakiraman
Journal:  J Istanb Univ Fac Dent       Date:  2017-12-02

Review 6.  Methods of Anterior Torque Control during Retraction: A Systematic Review.

Authors:  Anna Ewa Kuc; Jacek Kotuła; Marek Nahajowski; Maciej Warnecki; Joanna Lis; Ellie Amm; Beata Kawala; Michał Sarul
Journal:  Diagnostics (Basel)       Date:  2022-07-01

7.  Role of anatomical sites and correlated risk factors on the survival of orthodontic miniscrew implants: a systematic review and meta-analysis.

Authors:  Hisham Mohammed; Khaled Wafaie; Mumen Z Rizk; Mohammed Almuzian; Rami Sosly; David R Bearn
Journal:  Prog Orthod       Date:  2018-09-24       Impact factor: 2.750

Review 8.  Efficacy of orthodontic mini implants for en masse retraction in the maxilla: a systematic review and meta-analysis.

Authors:  Kathrin Becker; Annika Pliska; Caroline Busch; Benedict Wilmes; Michael Wolf; Dieter Drescher
Journal:  Int J Implant Dent       Date:  2018-10-25
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.