Validation of a video-based motion analysis technique in 3-D dynamic scapular kinematic measurements.

Yungchien Chu1, Jon Akins, Mita Lovalekar, Scott Tashman, Scott Lephart, Timothy Sell.   

Abstract

BACKGROUND: Current non-invasive 3-D scapular kinematic measurement techniques such as electromagnetic tracking are subjected to restrictions of wired sensors and limited capture space. Video-based motion analysis provides greater freedom with relatively less movement restriction. However, video-based motion analysis was rarely used in and not validated for scapular kinematics.
METHODS: Scapular kinematics of five subjects performing abduction, scaption, and internal/external rotation was captured simultaneously with video-based motion analysis and dynamic stereo X-ray, a gold standard for tracking scapular movements. The data from video-based motion analysis was correlated with the data from dynamic stereo X-ray for validity evaluation.
FINDINGS: Strong and significant correlations were identified in scapular protraction/retraction and medial/lateral rotation during abduction and scaption, and scapular medial/lateral rotation and anterior/posterior tilt during internal/external rotation.
INTERPRETATION: Video-based motion analysis is valid for evaluating a single subject's scapular movement pattern in protraction/retraction during abduction and scaption, and medial/lateral-rotation during internal/external rotation. Anterior/posterior-tilt during abduction and scaption should be investigated with caution. Video motion analysis is also valid for evaluating group average of scapular kinematics except for protraction/retraction during internal/external rotation. While acknowledging the inherent limitations, video-based motion analysis is an appropriate technique for tracking scapular kinematics.
Copyright © 2012 Elsevier Ltd. All rights reserved.

Mesh:

Year:  2012        PMID: 22898626     DOI: 10.1016/j.jbiomech.2012.06.025

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  2 in total

1.  Inter- and intrarater reliability of modified lateral scapular slide test in healthy athletic men.

Authors:  Azadeh Shadmehr; Mohammad Hassan Azarsa; Shohreh Jalaie
Journal:  Biomed Res Int       Date:  2014-05-13       Impact factor: 3.411

2.  Relationship between scapular control during isometric shoulder flexion and scapular motion during baseball pitching: a cross-sectional study.

Authors:  Yuki Nomura; Hajime Toda; Masaki Katayose; Shun Watanabe; Masahiro Yoshida; Makoto Yoshida; Keizo Yamamoto
Journal:  BMC Sports Sci Med Rehabil       Date:  2022-04-28