Literature DB >> 22897989

Real-time 3D echocardiographic quantification of left atrial volume: multicenter study for validation with CMR.

Victor Mor-Avi1, Chattanong Yodwut, Carly Jenkins, Harald Kühl, Hans-Joachim Nesser, Thomas H Marwick, Andreas Franke, Lynn Weinert, Johannes Niel, Regina Steringer-Mascherbauer, Benjamin H Freed, Lissa Sugeng, Roberto M Lang.   

Abstract

OBJECTIVES: We studied in a multicenter setting the accuracy and reproducibility of 3-dimensional echocardiography (3DE)-derived measurements of left atrial volume (LAV) using new, dedicated volumetric software, side by side with 2-dimensional echocardiography (2DE), using cardiac magnetic resonance (CMR) imaging as a reference.
BACKGROUND: Increased LAV is associated with adverse cardiovascular outcomes. Although LAV measurements are routinely performed using 2DE, this methodology is limited because it is view dependent and relies on geometric assumptions regarding left atrial shape. Real-time 3DE is free of these limitations and accordingly is an attractive alternative for the evaluation of LAV. However, few studies have validated 3DE-derived LAV measurements against an accepted independent reference standard, such as CMR imaging.
METHODS: We studied 92 patients with a wide range of LAV who underwent CMR (1.5-T) and echocardiographic imaging on the same day. Images were analyzed to obtain maximal and minimal LAV: CMR images using standard commercial tools, 2DE images using a biplane area-length technique, and 3DE images using Tomtec LA Function software. Intertechnique comparisons included linear regression and Bland-Altman analyses. Reproducibility of all 3 techniques was assessed by calculating the percentage of absolute differences in blinded repeated measurements. Kappa statistics were used to compare 2DE and 3DE classification of normal/enlarged against the CMR reference.
RESULTS: 3DE-derived LAV values showed higher correlation with CMR than 2DE measurements (r = 0.93 vs. r = 0.74 for maximal LAV; r = 0.88 vs. r = 0.82 for minimal LAV). Although 2DE underestimated maximal LAV by 31 ± 25 ml and minimal LAV by 16 ± 32 ml, 3DE resulted in a minimal bias of -1 ± 14 ml for maximal LAV and 0 ± 21 ml for minimal LAV. Interobserver and intraobserver variability of 2DE and 3DE measurements of maximal LAV were similar (7% to 12%) and approximately 2 times higher than CMR (4% to 5%). 3DE classified enlarged atria more accurately than 2DE (kappa: 0.88 vs. 0.71).
CONCLUSIONS: Compared with CMR reference, 3DE-derived LAV measurements are more accurate than 2DE-based analysis, resulting in fewer patients with undetected atrial enlargement.
Copyright © 2012 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22897989     DOI: 10.1016/j.jcmg.2012.05.011

Source DB:  PubMed          Journal:  JACC Cardiovasc Imaging        ISSN: 1876-7591


  56 in total

1.  Left atrial expansion index is an independent predictor of diastolic dysfunction in patients with preserved left ventricular systolic function: a three dimensional echocardiography study.

Authors:  Suzan Hatipoglu; Nihal Ozdemir; Gamze Babur Guler; Mehmet Onur Omaygenc; Ruken Bengi Bakal; Gokhan Kahveci; Tuba Unkun; Gulsum Sahin; Cihangir Kaymaz
Journal:  Int J Cardiovasc Imaging       Date:  2014-06-24       Impact factor: 2.357

Review 2.  Echocardiographic evaluation of left ventricular diastolic function: an update.

Authors:  Dimitrios Maragiannis; Sherif F Nagueh
Journal:  Curr Cardiol Rep       Date:  2015-02       Impact factor: 2.931

3.  Foreword.

Authors:  Andrew Js Coats; Giuseppe Rosano
Journal:  Card Fail Rev       Date:  2016-05

Review 4.  Three-Dimensional Echocardiography: Current Status and Real-Life Applications.

Authors:  Victor Chien-Chia Wu; Masaaki Takeuchi
Journal:  Acta Cardiol Sin       Date:  2017-03       Impact factor: 2.672

5.  Atrial-focused views improve the accuracy of two-dimensional echocardiographic measurements of the left and right atrial volumes: a contribution to the increase in normal values in the guidelines update.

Authors:  Kalie Kebed; Eric Kruse; Karima Addetia; Boguslawa Ciszek; Minnie Thykattil; Brittney Guile; Roberto M Lang; Victor Mor-Avi
Journal:  Int J Cardiovasc Imaging       Date:  2016-10-01       Impact factor: 2.357

6.  Real-time three-dimensional echocardiography of left atrial volume and function in patients with severe multi-vessel coronary artery disease.

Authors:  Lingjie Yang; Li Ma; Yanhong Li; Yuming Mu; Liyun Liu
Journal:  J Med Ultrason (2001)       Date:  2016-11-02       Impact factor: 1.314

7.  Machine learning based automated dynamic quantification of left heart chamber volumes.

Authors:  Akhil Narang; Victor Mor-Avi; Aldo Prado; Valentina Volpato; David Prater; Gloria Tamborini; Laura Fusini; Mauro Pepi; Neha Goyal; Karima Addetia; Alexandra Gonçalves; Amit R Patel; Roberto M Lang
Journal:  Eur Heart J Cardiovasc Imaging       Date:  2019-05-01       Impact factor: 6.875

Review 8.  EHRA/HRS/APHRS/SOLAECE expert consensus on atrial cardiomyopathies: Definition, characterization, and clinical implication.

Authors:  Andreas Goette; Jonathan M Kalman; Luis Aguinaga; Joseph Akar; Jose Angel Cabrera; Shih Ann Chen; Sumeet S Chugh; Domenico Corradi; Andre D'Avila; Dobromir Dobrev; Guilherme Fenelon; Mario Gonzalez; Stephane N Hatem; Robert Helm; Gerhard Hindricks; Siew Yen Ho; Brian Hoit; Jose Jalife; Young-Hoon Kim; Gregory Y H Lip; Chang-Sheng Ma; Gregory M Marcus; Katherine Murray; Akihiko Nogami; Prashanthan Sanders; William Uribe; David R Van Wagoner; Stanley Nattel
Journal:  Heart Rhythm       Date:  2016-06-10       Impact factor: 6.343

Review 9.  Principles of transthoracic echocardiographic evaluation.

Authors:  Anita C Boyd; Nelson B Schiller; Liza Thomas
Journal:  Nat Rev Cardiol       Date:  2015-04-28       Impact factor: 32.419

10.  Left atrial function in volume versus pressure overloaded left atrium.

Authors:  Michael Y Henein; Anders Holmgren; Per Lindqvist
Journal:  Int J Cardiovasc Imaging       Date:  2015-03-11       Impact factor: 2.357

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.