Literature DB >> 22894522

Reproducibility of near-infrared spectroscopy parameters measured during brachial artery occlusion and reactive hyperemia in healthy men.

Sébastien Lacroix1, Mathieu Gayda, Vincent Gremeaux, Martin Juneau, Jean-Claude Tardif, Anil Nigam.   

Abstract

Near-infrared spectroscopy (NIRS) is a noninvasive technique evaluating microvascular function. The aim of this study was to assess the reproducibility of NIRS parameters during reactive hyperemia induced by a 5 min brachial artery occlusion. Twenty-four healthy young males (mean 34 ± 8 years old) had two microvascular function evaluations by NIRS over a 7 to 30-day period (mean 16 ± 10 days). Intra-subject and inter-observer reproducibility were evaluated with intraclass correlation coefficient (ICC), coefficient of variation (CV), and standard error of measurement (SEM%) for every parameter. Mean NIRS parameters did not differ between both evaluations. Reproducibility was greatest for muscle oxygen consumption (ICC: 0.84; CV: 6.51%; SEM: 7.11%), time to basal O(2)Hb (ICC: 0.63, CV: 20.04%, SEM 27.22%), time to maximal O(2)Hb (ICC: 0.71; CV: 15.61%; SEM: 19.27%), peak of O(2)Hb (ICC: 0.63, CV: 6.68%, SEM 8.53%), time to maximal tHb (ICC: 0.73, CV: 19,61%, SEM 24.56%) and area under the O(2)Hb and tHb curves (ICC: 0.68, CV: 16.15%, SEM 22.93% and ICC: 0.62, CV: 18.59%, SEM 26.64%, respectively). Moreover, inter-observer reproducibility ranged from excellent to perfect (ICC from 0.85 to 1.00) for every parameter. NIRS parameters during reactive hyperemia are highly reproducible which enables their repeated measurement to study microvascular function in healthy subjects.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22894522     DOI: 10.1117/1.JBO.17.7.077010

Source DB:  PubMed          Journal:  J Biomed Opt        ISSN: 1083-3668            Impact factor:   3.170


  8 in total

1.  Skeletal Muscle Neurovascular Coupling, Oxidative Capacity, and Microvascular Function with 'One Stop Shop' Near-infrared Spectroscopy.

Authors:  Ryan Rosenberry; Susie Chung; Michael D Nelson
Journal:  J Vis Exp       Date:  2018-02-20       Impact factor: 1.355

2.  Hyperspectral imaging in wound care: A systematic review.

Authors:  Gennadi Saiko; Phoebe Lombardi; Yunghan Au; Douglas Queen; David Armstrong; Keith Harding
Journal:  Int Wound J       Date:  2020-08-23       Impact factor: 3.315

3.  Improved Exercise-Related Skeletal Muscle Oxygen Consumption Following Uptake of Endurance Training Measured Using Near-Infrared Spectroscopy.

Authors:  Siana Jones; Andrew D'Silva; Anish Bhuva; Guy Lloyd; Charlotte Manisty; James C Moon; Sanjay Sharma; Alun D Hughes
Journal:  Front Physiol       Date:  2017-12-12       Impact factor: 4.566

4.  Wearable and modular functional near-infrared spectroscopy instrument with multidistance measurements at four wavelengths.

Authors:  Dominik Wyser; Olivier Lambercy; Felix Scholkmann; Martin Wolf; Roger Gassert
Journal:  Neurophotonics       Date:  2017-08-18       Impact factor: 3.593

5.  Near-infrared spectroscopy-derived muscle oxygen saturation on a 0% to 100% scale: reliability and validity of the Moxy Monitor.

Authors:  Andri Feldmann; Roger Schmitz; Daniel Erlacher
Journal:  J Biomed Opt       Date:  2019-11       Impact factor: 3.170

6.  Type 2 diabetes does not account for ethnic differences in exercise capacity or skeletal muscle function in older adults.

Authors:  Siana Jones; Therese Tillin; Suzanne Williams; Sophie V Eastwood; Alun D Hughes; Nishi Chaturvedi
Journal:  Diabetologia       Date:  2019-12-09       Impact factor: 10.122

7.  Intra- and Inter-Day Reliability of the NIRS Portamon Device after Three Induced Muscle Ischemias.

Authors:  Julien Desanlis; Dan Gordon; Camille Calveyrac; François Cottin; Marie Gernigon
Journal:  Sensors (Basel)       Date:  2022-07-10       Impact factor: 3.847

Review 8.  Recent developments in near-infrared spectroscopy (NIRS) for the assessment of local skeletal muscle microvascular function and capacity to utilise oxygen.

Authors:  Siana Jones; Scott T Chiesa; Nishi Chaturvedi; Alun D Hughes
Journal:  Artery Res       Date:  2016-12       Impact factor: 0.597

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.