Literature DB >> 22892751

Failure of fiber posts after cementation with different adhesives with or without silanization investigated by pullout tests and scanning electron microscopy.

Yu Tian1, Yunjing Mu, Frank C Setzer, Hong Lu, Tiejun Qu, Qing Yu.   

Abstract

INTRODUCTION: The aim of the study was to test retentive forces of different adhesive systems after cementation of glass-fiber posts with or without prior silanization of the post by using a pullout test and scanning electron microscope (SEM) observation to detect the mode of failure.
METHODS: Fifty-six roots were randomly divided into 6 experimental and 2 control groups: ParaCore (PAR), Paracore + silane (PAR-SIL), RelyX Unicem (RXU), RelyX Unicem + silane (RXU-SIL), RelyX ARC (RXA), RelyX ARC + silane (RXA-SIL), negative control (NEG-CON), and positive control (POS-CON). ParaCore posts were placed in the experimental groups (each n = 8) by using an adhesive resin with or without prior silanization. NEG-CON received uncemented posts (n = 4); POS-CON received an active screw post with an adhesive (n = 4). All samples were subjected to a pullout test in a universal mechanical testing machine for pullout tests and SEM to assess the fiber posts and the roots after the tests.
RESULTS: Mean failure load values for each ground were PAR 247.4 ± 59.3 N, PAR-SIL 240.5 ± 68.8 N, RXU 102.3 ± 22.8 N, RXU-SIL 106.4 ± 19.8 N, RXA 119.8 ± 27.3 N, RXA-SIL 125.8 ± 28.3 N, NEG-CON 0 ± 0 N, and POS-CON 412.9 ± 27.4 N. There was a statistically significant difference between the 3 experimental adhesive systems (P < .001) and between each experimental group and NEG-CON and POS-CON (P < .05). PAR was significantly different from RXU and RXA (P < .05). No statistically significant differences existed between RXU and RXA and between the use of silanization or not. Representative samples for SEM showed cohesive failure as the principal fracture mode for PAR and mainly adhesive failure for RXU and RXA.
CONCLUSIONS: The results indicated that silanization of fiber posts does not make a difference to prevent dislocation of a post. Full-etching systems demonstrated significantly higher retentive forces than self-etching systems.
Copyright © 2012 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

Mesh:

Substances:

Year:  2012        PMID: 22892751     DOI: 10.1016/j.joen.2012.06.022

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  10 in total

Review 1.  Surface modification of glass fiber-reinforced composite posts to enhance their bond strength to resin-matrix cements: an integrative review.

Authors:  Júlio C M Souza; Valter Fernandes; Ana Correia; Paulo Miller; Oscar Carvalho; Filipe Silva; Mutlu Özcan; Bruno Henriques
Journal:  Clin Oral Investig       Date:  2021-10-28       Impact factor: 3.573

2.  Comparison of the effect of shear bond strength with silane and other three chemical presurface treatments of a glass fiber-reinforced post on adhesion with a resin-based luting agent: An in vitro study.

Authors:  Vaibhavi Ramkrishna Belwalkar; Jaykumar Gade; Nikhil Purushottam Mankar
Journal:  Contemp Clin Dent       Date:  2016 Apr-Jun

3.  Effect of laser heat treatment on Pull-out bond strength of fiber posts treated with different silanes.

Authors:  Fereshteh Shafiei; Maryam Saadat; Zahra Jowkar
Journal:  J Clin Exp Dent       Date:  2018-05-01

Review 4.  Effects of Surface Treatments of Glass Fiber-Reinforced Post on Bond Strength to Root Dentine: A Systematic Review.

Authors:  Lora Mishra; Abdul Samad Khan; Marilia Mattar de Amoedo Campos Velo; Saurav Panda; Angelo Zavattini; Fabio Antonio Piola Rizzante; Heber Isac Arbildo Vega; Salvatore Sauro; Monika Lukomska-Szymanska
Journal:  Materials (Basel)       Date:  2020-04-23       Impact factor: 3.623

5.  Effect of Glass Fiber Post Surface Treatment on Bond Strength of a Self-Adhesive Resin Cement: An "In Vitro" Study.

Authors:  Lairds Rodrigues Dos Santos; Darlon Martins Lima; Edilausson Moreno Carvalho; Vandilson Pinheiro Rodrigues; Claudia Maria Coelho Alves
Journal:  Int J Dent       Date:  2021-08-24

Review 6.  Effect of surface treatment on the dislocation resistance of prefabricated esthetic fiber posts bonded with self-adhesive resin cement: A systematic review and meta-analysis.

Authors:  Shweta Elizabeth Jacob; Sabah Mohd Zubair; Manuel Sebastian Thomas; Vinod Jathanna; Ramya Shenoy
Journal:  J Conserv Dent       Date:  2021-10-09

7.  Bond strength of cemented fiber posts to teeth with simulated internal root resorption.

Authors:  Ricardo-Toledo Abreu; Jaiane-Bandoli Monteiro; Amjad Abu-Hasna; Thaís-da Silva-Alves Santos; Amanda-Maria-de Oliveira Dal Piva; Cesar-Rogerio Pucci; Carlos-Rocha-Gomes Torres; Cláudio-Antonio-Talge Carvalho
Journal:  J Clin Exp Dent       Date:  2020-03-01

Review 8.  Current perspectives on dental adhesion: (3) Adhesion to intraradicular dentin: Concepts and applications.

Authors:  Mutlu Özcan; Claudia Angela Maziero Volpato
Journal:  Jpn Dent Sci Rev       Date:  2020-09-17

9.  Simulated damage of two implant debridement methods: Nonsurgical approach with Teflon and stainless steel hand scalers.

Authors:  João Paulo Mendes Tribst; Amanda Maria de Oliveira Dal Piva; Dimas Renno de Lima; Alexandre Luiz Souto Borges; Marco Antonio Bottino
Journal:  J Indian Soc Periodontol       Date:  2018 Jul-Aug

10.  Effects of motion direction and power of Er,Cr:YSGG laser on pull-out bond strength of fiber post to root dentin in endodontically-treated single-canal premolar teeth.

Authors:  Loghman Rezaei-Soufi; Leili Tapak; Mahsa Forouzande; Reza Fekrazad
Journal:  Biomater Res       Date:  2019-11-15
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.