Literature DB >> 22892741

Reaction of rat subcutaneous connective tissue to a mineral trioxide aggregate-based and a zinc oxide and eugenol sealer.

Osvaldo Zmener1, Ricardo Martinez Lalis, Cornelis H Pameijer, Carolina Chaves, Gabriel Kokubu, Daniel Grana.   

Abstract

INTRODUCTION: The purpose of this study was to evaluate the subcutaneous connective tissue reaction in rats to a mineral trioxide aggregate (MTA)-based endodontic sealer Fillapex (Angelus, Londrina, PR, Brazil) and compare it with Grossman sealer (Farmadental, Buenos Aires, Argentina).
METHODS: Sterile medical-grade silicone tubes containing the test materials were implanted in 24 Wistar rats. After 10, 30, and 90 days, the animals (n = 8 per period) were euthanized, and the implants along with their surrounding tissues were dissected, fixed, and processed for histologic evaluation. A 4-category evaluation system was used to evaluate the microscopic observations. The tissue response on the lateral walls of the silicone tubes was used as the negative control. The data were analyzed for statistical significance using the Wilcoxon signed rank, Kruskal-Wallis, and Dunn tests.
RESULTS: Fillapex showed a severe tissue reaction for all 3 observation periods. Grossman sealer showed similar features after 10 and 30 days, but the reaction decreased slightly after 90 days. In contrast, the negative controls did not show adverse reactions in any sample of the 3 time periods. After 10 and 30 days, no statistically significant differences were found between Fillapex and Grossman sealer (P > .05); however, the difference was significant after 90 days (P < .05). For all experimental periods, there were statistically significant differences between both Fillapex and Grossman sealer and the negative controls (P < .05).
CONCLUSIONS: It was concluded that both MTA-Fillapex and Grossman sealer remained toxic to subcutaneous tissues in rats after 90 days.
Copyright © 2012 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22892741     DOI: 10.1016/j.joen.2012.05.010

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  9 in total

1.  Ex Vivo Modeling of Multidomain Peptide Hydrogels with Intact Dental Pulp.

Authors:  A N Moore; S C Perez; J D Hartgerink; R N D'Souza; J S Colombo
Journal:  J Dent Res       Date:  2015-08-18       Impact factor: 6.116

2.  Cellular Responses in Human Dental Pulp Stem Cells Treated with Three Endodontic Materials.

Authors:  Alejandro Victoria-Escandell; José Santiago Ibañez-Cabellos; Sergio Bañuls-Sánchez de Cutanda; Ester Berenguer-Pascual; Jesús Beltrán-García; Eva García-López; Federico V Pallardó; José Luis García-Giménez; Antonio Pallarés-Sabater; Ignacio Zarzosa-López; Manuel Monterde
Journal:  Stem Cells Int       Date:  2017-05-24       Impact factor: 5.443

3.  Subcutaneous Connective Tissue Reaction to a New Nano Zinc-Oxide Eugenol Sealer in Rat Model.

Authors:  Salma Omidi; Maryam Javidi; Mina Zarei; Siavash Mushakhian; Amirhossein Jafarian
Journal:  Iran Endod J       Date:  2017

4.  Biocompatibility of new bioactive resin composite versus calcium silicate cements: an animal study.

Authors:  Ashraf Abou ElReash; Hamdi Hamama; Walied Abdo; Qiqi Wu; Ahmed Zaen El-Din; Xie Xiaoli
Journal:  BMC Oral Health       Date:  2019-08-22       Impact factor: 2.757

5.  Immunoinflammatory response and bioactive potential of GuttaFlow bioseal and MTA Fillapex in the rat subcutaneous tissue.

Authors:  Mateus Machado Delfino; Juliane Maria Guerreiro-Tanomaru; Mário Tanomaru-Filho; Estela Sasso-Cerri; Paulo Sérgio Cerri
Journal:  Sci Rep       Date:  2020-04-28       Impact factor: 4.379

Review 6.  Biocompatibility of Root Canal Sealers: A Systematic Review of In Vitro and In Vivo Studies.

Authors:  Diogo Afonso Fonseca; Anabela Baptista Paula; Carlos Miguel Marto; Ana Coelho; Siri Paulo; José Pedro Martinho; Eunice Carrilho; Manuel Marques Ferreira
Journal:  Materials (Basel)       Date:  2019-12-09       Impact factor: 3.623

7.  Rat subcutaneous tissue response to calcium silicate containing different arsenic concentrations.

Authors:  Paloma Gagliardi Minotti; Ronald Ordinola-Zapata; Raquel Zanin Midena; Marina Angélica Marciano; Bruno Cavalini Cavenago; Clovis Monteiro Bramante; Roberto Brandão Garcia; Marco Antonio Hungaro Duarte; Ivaldo Gomes de Moraes
Journal:  J Appl Oral Sci       Date:  2014-07-29       Impact factor: 2.698

8.  Physicochemical properties and surfaces morphologies evaluation of MTA FillApex and AH plus.

Authors:  Álvaro Henrique Borges; Maura Cristiane Gonçales Orçati Dorileo; Ricardo Dalla Villa; Alexandre Meireles Borba; Tereza Aparecida Delle Vedove Semenoff; Orlando Aguirre Guedes; Cyntia Rodrigues Araújo Estrela; Matheus Coelho Bandeca
Journal:  ScientificWorldJournal       Date:  2014-05-04

9.  Comparative Evaluation of Cytotoxic and Genotoxic Effects of Three Resin-Based Sealers by 3,(4,5-Dimethylthiazol-2-yl)-2,5-Diphenyltetrazolium Bromide Assay and Comet Assay - An In Vitro Study.

Authors:  Vaidehi Vikas Dhopavkar; Sunita S Shivanand; Kishore Bhat; Anand C Patil; Preeti K Doddwad; Niraj Jayant Godbole
Journal:  Contemp Clin Dent       Date:  2021-12-21
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.