Removal of fractured dental implant screw using a new technique: a case report.

Manpreet S Walia1, Saryu Arora, Reena Luthra, Prabhjot Kaur Walia.   

Abstract

Implant restorations can fail biologically or mechanically. Biological factors include unsuccessful osseointegration or presence of peri-implantitis. Mechanical failures include crown fracture, framework fracture, screw loosening, and screw fracture. Fracture of the implant abutment can be a serious problem as the fragment remaining inside the implant may prevent the implant from functioning efficiently. The procedure used for removal of the fractured screw portion is described in this clinical report.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22891679     DOI: 10.1563/AAID-JOI-D-10-00195

Source DB:  PubMed          Journal:  J Oral Implantol        ISSN: 0160-6972            Impact factor:   1.779


  4 in total

Review 1.  Management of perishing implants with abutment screw fracture - A systematic review.

Authors:  Soja Raju; Vivek V Nair; Harsha Kumar Karunakaran; Noxy George Manjuran
Journal:  J Indian Prosthodont Soc       Date:  2021 Jul-Sep

Review 2.  Complications in implant dentistry.

Authors:  Ayesha Hanif; Saima Qureshi; Zeeshan Sheikh; Haroon Rashid
Journal:  Eur J Dent       Date:  2017 Jan-Mar

3.  A novel technique to retrieve cold-welded implant abutment: A case series.

Authors:  Mahnaz Arshad; Hossein Ali Mahgoli; Kamran Rasouli; Sina Refoua
Journal:  Clin Case Rep       Date:  2019-08-16

4.  Biomechanical effects of original equipment manufacturer and aftermarket abutment screws in zirconia abutment on dental implant assembly.

Authors:  Yu-Ling Wu; Ming-Hsu Tsai; Hung-Shyong Chen; Yu-Tsen Chang; Tsai-Te Lin; Aaron Yu-Jen Wu
Journal:  Sci Rep       Date:  2020-10-27       Impact factor: 4.379

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.