Literature DB >> 22890198

Dry eye symptoms in patients after eyelid reconstruction with full-thickness eyelid defects: using the Tomey TG-1000 thermographer.

Johannes Gonnermann1, Julian P Klein, Matthias K J Klamann, Anna-Karina Maier, Uwe Pleyer, Antonia M Joussen, Eckart Bertelmann.   

Abstract

BACKGROUND: Large full-thickness eyelid defects are conventionally reconstructed by either a Hughes flap or Cutler-Beard bridge flap. Since the structure of the eyelid and its components are necessary for the tear film production and stability, we investigated the outcome after eyelid reconstruction focusing on dry eye symptoms using a new thermographic device, the TG-1000.
METHODS: Seventeen eyes of patients formerly treated with Hughes flaps (n = 16) and a Cutler-Beard bridge flap (n = 1) were compared to untreated healthy eyes (n = 17) regarding the functional and aesthetic outcome. The follow-up ranged from 3 to 63 months (mean 24.88 ± 17.86).
RESULTS: There was no significant difference in Schirmer's test, break-up time and ocular surface temperature (p > 0.05) between patients after full-thickness eyelid reconstruction and a control group. Eleven patients had minor postoperative complications such as notching of the lid margin (11/17), epiphora (1/17), superficial punctate keratitis (6/17), trichiasis (2/17) and a mild tendency to eversion of the lid margin (6/17). More than 75% of the patients rated their postoperative aesthetic outcome as good or even excellent.
CONCLUSION: The new TG-1000 device is a simple and quick tool for screening of dry eye. This study shows that tarsoconjunctival grafts offer good aesthetic and functional outcome with sufficient tear film composition and stability.
Copyright © 2012 S. Karger AG, Basel.

Entities:  

Mesh:

Year:  2012        PMID: 22890198     DOI: 10.1159/000339598

Source DB:  PubMed          Journal:  Ophthalmic Res        ISSN: 0030-3747            Impact factor:   2.892


  3 in total

1.  [Interobserver and intraobserver reliability of corneal surface temperature measurements with the TG-1000 thermograph in normal eyes].

Authors:  M Pattmöller; J Wang; J Pattmöller; E Zemova; T Eppig; B Seitz; N Szentmáry; A Langenbucher
Journal:  Ophthalmologe       Date:  2015-09       Impact factor: 1.059

Review 2.  Application of infrared thermography in computer aided diagnosis.

Authors:  Oliver Faust; U Rajendra Acharya; E Y K Ng; Tan Jen Hong; Wenwei Yu
Journal:  Infrared Phys Technol       Date:  2014-06-20       Impact factor: 2.638

3.  Modified Hughes procedure for reconstruction of large full-thickness lower eyelid defects following tumor resection.

Authors:  Ahmed M Hishmi; Konrad R Koch; Mario Matthaei; Edwin Bölke; Claus Cursiefen; Ludwig M Heindl
Journal:  Eur J Med Res       Date:  2016-06-30       Impact factor: 2.175