Literature DB >> 22889992

Comparison of amino acid derivatization reagents for LC-ESI-MS analysis. Introducing a novel phosphazene-based derivatization reagent.

Riin Rebane1, Maarja-Liisa Oldekop, Koit Herodes.   

Abstract

Amino acid analysis with high performance liquid chromatography with electrospray ionization mass spectrometry (LC-ESI-MS) is an emerging method. For more sensitive analysis, derivatization is used and next to commercially available derivatization reagents such as dansyl chloride (DNS), 9-fluorenylmethyl chloroformate (FMOC-Cl) and diethyl ethoxymethylenemalonate (DEEMM), new derivatization reagents are designed specially for LC-ESI-MS, like p-N,N,N-trimethylammonioanilyl N'-hydroxysuccinimidyl carbamate iodide (TAHS) which provides very low limits of detection. In this work, a novel phosphazene based derivatization reagent (FOSF) that provides comparable limits of quantitation (LoQ) to TAHS is introduced. Moreover, a thorough comparison between FOSF, TAHS, DNS, FMOC-Cl and DEEMM is carried out for 7 different amino acids - Arg, Asp, Gly, β-Ala, Pro, Trp and Phe. This is a first time that thorough comparison is carried out on the same instrument for amino acid derivatization reagents. Results on the same instrument for five amino acid derivatization reagents show that novel reagents are sensitive with LoQ values around 80 fmol but have disadvantages such as problematic chromatographic separation. Next to novel reagents, DEEMM offers very good LoQ-s (average of 150 fmol) and wide dynamic linear range.
Copyright © 2012 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22889992     DOI: 10.1016/j.jchromb.2012.07.029

Source DB:  PubMed          Journal:  J Chromatogr B Analyt Technol Biomed Life Sci        ISSN: 1570-0232            Impact factor:   3.205


  5 in total

1.  Quantification of hypoglycin A and methylenecyclopropylglycine in human plasma by HPLC-MS/MS.

Authors:  Aimee A Sanford; Samantha L Isenberg; Melissa D Carter; Mike A Mojica; Thomas P Mathews; Sarah Laughlin; Jerry D Thomas; James L Pirkle; Rudolph C Johnson
Journal:  J Chromatogr B Analyt Technol Biomed Life Sci       Date:  2018-07-20       Impact factor: 3.205

2.  High performance liquid chromatography-electrospray ionization mass spectrometric (LC-ESI-MS) methodology for analysis of amino acid energy substrates in microwave-fixed microdissected brain tissue.

Authors:  Khaggeswar Bheemanapally; Mostafa M H Ibrahim; Karen P Briski
Journal:  J Pharm Biomed Anal       Date:  2020-01-28       Impact factor: 3.935

Review 3.  The Role of Branched-Chain Amino Acids and Branched-Chain α-Keto Acid Dehydrogenase Kinase in Metabolic Disorders.

Authors:  Chuang Du; Wen-Jie Liu; Jing Yang; Shan-Shan Zhao; Hui-Xin Liu
Journal:  Front Nutr       Date:  2022-07-18

4.  Mass spectrometry with derivatization method for concurrent measurement of amino acids and acylcarnitines in plasma of diabetic type 2 patients with diabetic nephropathy.

Authors:  Parsa Esmati; Niloufar Najjar; Solaleh Emamgholipour; Shaghayegh Hosseinkhani; Babak Arjmand; Amin Soleimani; Ardeshir Kakaii; Farideh Razi
Journal:  J Diabetes Metab Disord       Date:  2021-03-29

5.  Mass spectrometry imaging of amino neurotransmitters: a comparison of derivatization methods and application in mouse brain tissue.

Authors:  Clara Esteve; Else A Tolner; Reinald Shyti; Arn M J M van den Maagdenberg; Liam A McDonnell
Journal:  Metabolomics       Date:  2016-01-08       Impact factor: 4.290

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.