Literature DB >> 22888082

Intraprocedural evaluation of fine-needle aspiration smears: how good are we?

Rachel Factor1, Lester J Layfield.   

Abstract

A significant percentage of fine-needle aspirations (FNAs) is obtained using radiographic image guidance. Such image-guided aspirates are associated with increased costs, and it is highly desirable that adequate material for diagnosis is obtained at the time of the initial procedure. Hence, intraoperative evaluation of smear material is frequently performed to evaluate adequacy and to triage the aspirate to specialized tests such as flow cytometry and cytogenetics for appropriate work-up. Although FNA under radiologic guidance has been shown to be useful, little data exist as to the accuracy of such intraprocedural evaluation. The quality-assurance records between May 2009 and May 2010 were electronically searched for all FNA cases with intraprocedural evaluation. The reports were obtained and reviewed to compare the intraprocedural diagnosis and the final cytopathologic diagnosis. Percentage of deferred cases and percentage of disagreement were calculated. From May 2009 to May 2010, a total of 775 FNAs were performed with intraprocedural review. These cases were reviewed by seven board-certified cytopathologists. In 738 cases, the preliminary interpretation agreed with the final diagnosis. In 2.2% (17 of 775) of cases, the interpretation was deferred until-cell block, and/or cytospin preparations were obtained. In 2.6% (20 of 775) of cases, a disagreement in diagnosis existed between the initial interpretation and the final sign-out diagnosis. Intraprocedural interpretation of FNA material appears to be highly reliable with disagreements occurring in only 2.6% of cases. This degree of disagreement is slightly higher than that reported in some frozen section studies.
Copyright © 2011 Wiley Periodicals, Inc.

Mesh:

Year:  2011        PMID: 22888082     DOI: 10.1002/dc.21618

Source DB:  PubMed          Journal:  Diagn Cytopathol        ISSN: 1097-0339            Impact factor:   1.582


  2 in total

1.  Utility of on-site evaluation of endobronchial ultrasound-guided transbronchial needle aspiration specimens.

Authors:  Adrienne Carruth Griffin; Lauren Ende Schwartz; Zubair W Baloch
Journal:  Cytojournal       Date:  2011-11-21       Impact factor: 2.091

2.  Fine needle aspirate flow cytometric phenotyping characterizes immunosuppressive nature of the mesothelioma microenvironment.

Authors:  Patrick H Lizotte; Robert E Jones; Lauren Keogh; Elena Ivanova; Hongye Liu; Mark M Awad; Peter S Hammerman; Ritu R Gill; William G Richards; David A Barbie; Adam J Bass; Raphael Bueno; Jessie M English; Mark Bittinger; Kwok-Kin Wong
Journal:  Sci Rep       Date:  2016-08-19       Impact factor: 4.379

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.