Literature DB >> 22886780

Commissioning of MRI-only based treatment planning procedure for external beam radiotherapy of prostate.

Mika Kapanen1, Juhani Collan, Annette Beule, Tiina Seppälä, Kauko Saarilahti, Mikko Tenhunen.   

Abstract

In radiotherapy, target tissues are defined best on MR images due to their superior soft tissue contrast. Computed tomography imaging is geometrically accurate and it is needed for dose calculation and generation of reference images for treatment localization. Co-registration errors between MR and computed tomography images can be eliminated using magnetic resonance imaging-only based treatment planning. Use of ionizing radiation can be avoided which is especially important in adaptive treatments requiring several re-scans. We commissioned magnetic resonance imaging-only based procedure for external radiotherapy, treatment planning of the prostate cancer. Geometrical issues relevant in radiotherapy, were investigated including quality assurance testing of the scanner, evaluation of the displacement of skin contour and radiosensitive rectum wall, and detection of intraprostatic fiducial gold seed markers used for treatment localization. Quantitative analysis was carried out for 30 randomly chosen patients. Systematic geometrical errors were within 2.2 mm. The gold seed markers were correctly identified for 29 out of the 30 patients. Positions of the seed midpoints were consistent within 1.3 mm in magnetic resonance imaging and computed tomography. Positional error of rectal anterior wall due to susceptibility effect was minimal. Geometrical accuracy of the investigated equipment and procedure was sufficient for magnetic resonance imaging-only based radiotherapy, treatment planning of the prostate cancer including treatment virtual simulation.
Copyright © 2012 Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2012        PMID: 22886780     DOI: 10.1002/mrm.24459

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  28 in total

1.  MR simulation for prostate radiation therapy: effect of coil mounting position on image quality.

Authors:  J Sun; P Pichler; J Dowling; F Menk; P Stanwell; J Arm; P B Greer
Journal:  Br J Radiol       Date:  2014-07-25       Impact factor: 3.039

2.  Effect of region extraction and assigned mass-density values on the accuracy of dose calculation with magnetic resonance-based volumetric arc therapy planning.

Authors:  Keisuke Usui; Keisuke Sasai; Koichi Ogawa
Journal:  Radiol Phys Technol       Date:  2018-03-14

3.  Penile bulb sparing in prostate cancer radiotherapy : Dose analysis of an in-house MRI system to improve contouring.

Authors:  F Böckelmann; M Hammon; S Lettmaier; R Fietkau; C Bert; F Putz
Journal:  Strahlenther Onkol       Date:  2018-10-12       Impact factor: 3.621

4.  Effect of age-dependent bone electron density on the calculated dose distribution from kilovoltage and megavoltage photon and electron radiotherapy in paediatric MRI-only treatment planning.

Authors:  B Zeinali-Rafsanjani; R Faghihi; M A Mosleh-Shirazi; M Saeedi-Moghadam; R Jalli; S Sina
Journal:  Br J Radiol       Date:  2017-11-09       Impact factor: 3.039

5.  Converting from CT- to MRI-only-based target definition in radiotherapy of localized prostate cancer: A comparison between two modalities.

Authors:  Tiina Seppälä; Harri Visapää; Juhani Collan; Mika Kapanen; Annette Beule; Mauri Kouri; Mikko Tenhunen; Kauko Saarilahti
Journal:  Strahlenther Onkol       Date:  2015-07-14       Impact factor: 3.621

Review 6.  MRI-only treatment planning: benefits and challenges.

Authors:  Amir M Owrangi; Peter B Greer; Carri K Glide-Hurst
Journal:  Phys Med Biol       Date:  2018-02-26       Impact factor: 3.609

7.  MRI-Based Proton Treatment Planning for Base of Skull Tumors.

Authors:  Ghazal Shafai-Erfani; Yang Lei; Yingzi Liu; Yinan Wang; Tonghe Wang; Jim Zhong; Tian Liu; Mark McDonald; Walter J Curran; Jun Zhou; Hui-Kuo Shu; Xiaofeng Yang
Journal:  Int J Part Ther       Date:  2019-09-30

8.  Comparison of MRI sequences in ideal fiducial maker-based radiotherapy for prostate cancer.

Authors:  Osamu Tanaka; Hisao Komeda; Mitsuyoshi Hattori; Shigeki Hirose; Eiichi Yama; Masayuki Matsuo
Journal:  Rep Pract Oncol Radiother       Date:  2017-11-01

9.  Are cone beam CT image matching skills transferrable from planning CT to planning MRI for MR-only prostate radiotherapy?

Authors:  Rachel L Brooks; Hazel M McCallum; Rachel A Pearson; Karen Pilling; Jonathan Wyatt
Journal:  Br J Radiol       Date:  2021-04-29       Impact factor: 3.039

10.  Radiotherapy planning using MRI.

Authors:  Maria A Schmidt; Geoffrey S Payne
Journal:  Phys Med Biol       Date:  2015-10-28       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.