Literature DB >> 22883750

Sensitive label-free electrochemical analysis of human IgE using an aptasensor with cDNA amplification.

Cheng-Yu Lee1, Kuan-Ying Wu, Hsiu-Li Su, Huan-Yi Hung, You-Zung Hsieh.   

Abstract

In this study, we developed an ultrasensitive label-free aptamer-based electrochemical biosensor, featuring a highly specific anti-human immunoglobulin E (IgE) aptamer as a capture probe, for human IgE detection. Construction of the aptasensor began with the electrodeposition of gold nanoparticles (AuNPs) onto a graphite-based screen-printed electrode (SPE). After immobilizing the thiol-capped anti-human IgE aptamer onto the AuNPs through self-assembly, we treated the electrode with mercaptohexanol (MCH) to ensure that the remaining unoccupied surfaces of the AuNPs would not undergo nonspecific binding. We employed a designed complementary DNA featuring a guanine-rich section in its sequence (cDNA G1) as a detection probe to bind with the unbound anti-human IgE aptamer. We measured the redox current of methylene blue (MB) to determine the concentration of human IgE in the sample. When the aptamer captured human IgE, the binding of cDNA G1 to the aptamer was inhibited. Using cDNA G1 in the assay greatly amplified the redox signal of MB bound to the detection probe. Accordingly, this approach allowed the linear range (coefficient of determination: 0.996) for the analysis of human IgE to extend from 1 to 100,000pM; the limit of detection was 0.16pM. The fabricated aptasensor exhibited good selectivity toward human IgE even when human IgG, thrombin, and human serum albumin were present at 100-fold concentrations. This method should be readily applicable to the detection of other analytes, merely by replacing the anti-human IgE aptamer/cDNA G1 pair with a suitable anti-target molecule aptamer and cDNA.
Copyright © 2012 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22883750     DOI: 10.1016/j.bios.2012.07.009

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  2 in total

Review 1.  Biosensors for Detecting Lymphocytes and Immunoglobulins.

Authors:  Pietro Salvo; Federico M Vivaldi; Andrea Bonini; Denise Biagini; Francesca G Bellagambi; Filippo M Miliani; Fabio Di Francesco; Tommaso Lomonaco
Journal:  Biosensors (Basel)       Date:  2020-10-27

Review 2.  Aptamers against Immunoglobulins: Design, Selection and Bioanalytical Applications.

Authors:  Zsófia Bognár; Róbert E Gyurcsányi
Journal:  Int J Mol Sci       Date:  2020-08-11       Impact factor: 5.923