Literature DB >> 22878383

Evaluation of 0.3% gatifloxacin hydrochloride in decontamination of donor corneas.

Namrata Sharma1, Amarendra Samal, Reena Sharma, Radhika Tandon, Jeewan S Titiyal, Gita Satpathy, Seema Sen, Rasik B Vajpayee.   

Abstract

PURPOSE: To evaluate demographic, clinical, and microbiological profile of eye donors and efficacy of 0.3% gatifloxacin hydrochloride in microbial decontamination of donor corneas.
METHODS: About 513 donors and 1,026 corneas received at National Eye Bank of a tertiary care hospital during 1-year period were analyzed prospectively in this randomized clinical trial. The donor eyes were graded and treated with 5% povidone-iodine, 0.4% amikacin sulphate, and 0.3% gatifloxacin hydrochloride. The parameters evaluated were death enucleation time (DET), grading of donor corneas, microbiological profile of culture organisms, and their sensitivity to various antibiotics.
RESULTS: Mean DET was 6.29±5.7 hours. Forty one percent eyes were optical grade corneas and the majority of donors (38.5%) had accidental deaths. Good grade eyes were maximum with DET of <1 hour and were comparable between 0-6 hours and 6-12 hours. About 57.6% (591/1026) eyes were culture positive; most common organisms were Pseudomonas spp (53%) and Coagulase-negative Staphylococci (24%). Culture positivity reduced significantly after treatment with povidone iodine and amikacin (P=0.002, right eye; P=0.004; left eye) and decreased further with use of gatifloxacin (P=0.001). Pseudomonas (93%), Coagulase-negative Staphylococci (96.3%), Staphylococcus aureus (90.5%), enterococci and gram-negative bacilli were sensitive to gatifloxacin. Pseudomonas spp which were multidrug-resistant were sensitive to polymyxin-B.
CONCLUSIONS: Gatifloxacin hydrochloride in addition to amikacin sulphate is beneficial for donor eye decontamination. Polymyxin-B may be used for multidrug-resistant Pseudomonas spp.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22878383     DOI: 10.1097/ICL.0b013e3182657ba1

Source DB:  PubMed          Journal:  Eye Contact Lens        ISSN: 1542-2321            Impact factor:   2.018


  3 in total

Review 1.  Upgradation and modernization of eye banking services: Integrating tradition with innovative policies and current best practices.

Authors:  Radhika Tandon; Archita Singh; Noopur Gupta; M Vanathi; Vivek Gupta
Journal:  Indian J Ophthalmol       Date:  2017-02       Impact factor: 1.848

2.  Response to comment on: Microbiological profile of eye donors and the effectiveness of ocular surface decontaminants during in situ corneal retrieval.

Authors:  Prabhakar Singh; Radhika Tandon
Journal:  Indian J Ophthalmol       Date:  2022-01       Impact factor: 1.848

3.  Microbiological profile of eye donors and the effectiveness of ocular surface decontaminants during in situ corneal retrieval.

Authors:  Prabhakar Singh; Radhika Tandon
Journal:  Indian J Ophthalmol       Date:  2021-07       Impact factor: 1.848

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.