Literature DB >> 2287535

The value of Doppler sonography in the detection of major vessel thrombosis in the neonatal abdomen.

D A Stringer1, J Krysl, D Manson, C Babiak, A Daneman, P Liu.   

Abstract

Duplex spectral or color Doppler sonography demonstrated major abdominal vessel blocks affecting 18 vessels in 16 infants aged between 23 and 56 weeks postconceptional age. The portal vein was affected in 8 infants, the renal vein in 3, the renal vein and inferior vena cava in 1, the renal artery in 1, the inferior vena cava and hepatic vein in 1, and the aorta in 2 infants. Doppler sonography confirmed the grey-scale findings and often demonstrated the extent of vascular flow, providing functional information not available from the grey-scale scan. It facilitated the follow-up of thrombosis during therapy. Most important of all, in many instances it enabled a rapid and reliable specific diagnosis often not possible on the grey-scale study alone and hence altered patient management.

Entities:  

Mesh:

Year:  1990        PMID: 2287535     DOI: 10.1007/bf02010810

Source DB:  PubMed          Journal:  Pediatr Radiol        ISSN: 0301-0449


  12 in total

1.  Arterial occlusions in neonates: use of fibrinolytic therapy.

Authors:  J L Strife; W S Ball; R Towbin; M S Keller; T Dillon
Journal:  Radiology       Date:  1988-02       Impact factor: 11.105

2.  Sonography of experimental acute renal vein occlusion.

Authors:  M R Paling; J A Wakefield; L R Watson
Journal:  J Clin Ultrasound       Date:  1985 Nov-Dec       Impact factor: 0.910

3.  Ultrasound imaging of inferior vena cava thrombosis.

Authors:  R Goiney
Journal:  J Ultrasound Med       Date:  1985-07       Impact factor: 2.153

4.  Duplex Doppler: identification of cavernous transformation of the portal vein.

Authors:  G Weltin; K J Taylor; A R Carter; C R Taylor
Journal:  AJR Am J Roentgenol       Date:  1985-05       Impact factor: 3.959

5.  Porta hepatis: sonographic discrimination of bile ducts from arteries with pulsed Doppler with new anatomic criteria.

Authors:  L L Berland; T L Lawson; W D Foley
Journal:  AJR Am J Roentgenol       Date:  1982-05       Impact factor: 3.959

6.  Assessment of portal vein patency: comparison of arterial portography and ultrasound scanning.

Authors:  N Raby; J Karani; P Powell-Jackson; H Meire; R Williams
Journal:  Clin Radiol       Date:  1988-07       Impact factor: 2.350

7.  Sonographic detection of neonatal umbilical-artery thrombosis: clinical correlation.

Authors:  J J Seibert; B J Taylor; S L Williamson; B J Williams; J S Szabo; S L Corbitt
Journal:  AJR Am J Roentgenol       Date:  1987-05       Impact factor: 3.959

8.  Aortic thrombosis diagnosed by ultrasound.

Authors:  G Rudas; S Bors
Journal:  Pediatr Radiol       Date:  1988

9.  Duplex Doppler examination in portal hypertension: technique and anatomy.

Authors:  H Patriquin; M Lafortune; P N Burns; M Dauzat
Journal:  AJR Am J Roentgenol       Date:  1987-07       Impact factor: 3.959

10.  Neonatal aortic thrombosis treated with intra-arterial urokinase therapy.

Authors:  R E Goldberg; A M Cohen; P J Bryan; M Olsen; R J Martin
Journal:  Can Assoc Radiol J       Date:  1989-02       Impact factor: 2.248

View more
  4 in total

Review 1.  Pediatric applications of abdominal vascular Doppler: Part II.

Authors:  Brian D Coley
Journal:  Pediatr Radiol       Date:  2004-08-05

Review 2.  Pediatric applications of abdominal vascular Doppler imaging: Part I.

Authors:  Brian D Coley
Journal:  Pediatr Radiol       Date:  2004-07-27

3.  Diagnosis of neonatal aortic thrombosis by colour coded Doppler sonography.

Authors:  K H Deeg; D Wölfel; T Rupprecht
Journal:  Pediatr Radiol       Date:  1992

Review 4.  Renal vein thrombosis in the neonate: a case report and review of the literature.

Authors:  Ifeoma C Anochie; Felicia Eke
Journal:  J Natl Med Assoc       Date:  2004-12       Impact factor: 1.798

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.