SIScaR-GPU: fast simulation and visualization of intraoperative scattered radiation to support radiation protection training.

Markus Wagner1, Klaus Dresing, Wolfram Ludwig, Christoph Alexander Ahrens, Oliver J Bott.   

Abstract

Scattered radiation caused by the intraoperative use of mobile image intensifier systems (referred to as "C-arms") is the main source of radiation exposure for operating room personnel and surgeons. To keep this possibly harmful exposure at a minimum level, a deliberate use of radiation, knowledge about distribution of scattered radiation and appropriate behavior pattern are indispensable. Therefore in several countries knowledge concerning these aspects is taught in mandatory courses on radiation protection. Currently this teaching is typically based on non-interactive didactical methods (texts, pictures and videos). Because of the complexity of the knowledge field this restriction might lead to an insufficient understanding of the facts, an inappropriate behavior and therefore to an avoidable radiation exposure. This paper presents a new software module, which is able to simulate and visualize intraoperative radiation distribution and the resulting dose values for the attending persons within a few seconds (less than 30s). The developed components, which simulate the radiation transport using a graphics processing unit three times faster than comparable approaches, were integrated exemplarily in the computer based C-arm training system virtX. This extended training system improves the teaching through a prompt visual feedback on non-trivial scattered radiation facts in freely adoptable situations.

Entities:  

Mesh:

Year:  2012        PMID: 22874337

Source DB:  PubMed          Journal:  Stud Health Technol Inform        ISSN: 0926-9630


  3 in total

1.  Seeing is believing: increasing intraoperative awareness to scattered radiation in interventional procedures by combining augmented reality, Monte Carlo simulations and wireless dosimeters.

Authors:  Nicolas Loy Rodas; Nicolas Padoy
Journal:  Int J Comput Assist Radiol Surg       Date:  2015-02-26       Impact factor: 2.924

2.  Simulation of scattered radiation during intraoperative imaging in a virtual reality learning environment.

Authors:  Matthias Süncksen; Oliver Johannes Bott; Klaus Dresing; Michael Teistler
Journal:  Int J Comput Assist Radiol Surg       Date:  2020-03-04       Impact factor: 2.924

3.  Real-time, ray casting-based scatter dose estimation for c-arm x-ray system.

Authors:  Zaid Alnewaini; Eric Langer; Philipp Schaber; Matthias David; Dominik Kretz; Volker Steil; Jürgen Hesser
Journal:  J Appl Clin Med Phys       Date:  2017-01-24       Impact factor: 2.102

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.