Literature DB >> 22872521

Intraoperative ultrasound guidance for excision of non-palpable invasive breast cancer: a hospital-based series and an overview of the literature.

M W Barentsz1, T van Dalen, P D Gobardhan, V Bongers, C I Perre, R M Pijnappel, M A A J van den Bosch, H M Verkooijen.   

Abstract

Intraoperative ultrasound (IOUS) can be used in the operation theatre for localization of non-palpable breast cancers. In this prospective cohort study, we compared the yield of IOUS to guidewire localization (GWL). A total of 258 consecutive patients with non-palpable invasive breast cancer underwent breast conserving surgery between 1999 and 2010. GWL was performed in 138 (54 %) and IOUS in 120 (46 %) patients. Tumor dimensions, resection volume, margin status and re-excision rates were compared by means of multivariate regression analysis. The groups were similar in terms of age, histological subtype and presence of DCIS. Lesions in the IOUS group were larger (1.24 vs. 0.98 cm, P < 0.001), while microcalcifications were more common in the GWL group (19 vs. 3 %, P < 0.001). Even after stratification for tumor diameter, presence of DCIS and findings on mammography, resection volumes were similar in both groups. Tumor-free resection margins were obtained in >93 % of patients (93.5 % with GWL vs. 93.3 % with IOUS, P = 0.958) and re-excision was performed in 11 % of patients undergoing GWL and 12.5 % of patients undergoing IOUS (P = 0.684). For localization of non-palpable breast cancer, IOUS is a reliable alternative to GWL, as it achieves similar results in terms of complete tumor removal, re-excision rate and excised volume.

Entities:  

Mesh:

Year:  2012        PMID: 22872521     DOI: 10.1007/s10549-012-2165-7

Source DB:  PubMed          Journal:  Breast Cancer Res Treat        ISSN: 0167-6806            Impact factor:   4.872


  15 in total

1.  Ultrasound-guided preoperative localization of breast lesions: a good choice.

Authors:  Giorgio Carlino; Pierluigi Rinaldi; Michela Giuliani; Rossella Rella; Enida Bufi; Federico Padovano; Chiara Ciardi; Maurizio Romani; Paolo Belli; Riccardo Manfredi
Journal:  J Ultrasound       Date:  2018-10-26

2.  The role of intraoperative ultrasound in breast-conserving surgery of nonpalpable breast cancer.

Authors:  Nina Čas Sikošek; Andraž Dovnik; Darja Arko; Iztok Takač
Journal:  Wien Klin Wochenschr       Date:  2014-01-18       Impact factor: 1.704

Review 3.  Current status of ultrasound-guided surgery in the treatment of breast cancer.

Authors:  José H Volders; Max H Haloua; Nicole Ma Krekel; Sybren Meijer; Petrousjka M van den Tol
Journal:  World J Clin Oncol       Date:  2016-02-10

4.  Combined LOCalizer™ and Intraoperative Ultrasound Localization: First Experience in Localization of Non-palpable Breast Cancer.

Authors:  Simona Parisi; Roberto Ruggiero; Giorgia Gualtieri; Mariachiara Lanza Volpe; Serena Rinaldi; Giusiana Nesta; Lidija Bogdanovich; Francesco Saverio Lucido; Salvatore Tolone; Domenico Parmeggiani; Claudio Gambardella; Ludovico Docimo
Journal:  In Vivo       Date:  2021 May-Jun       Impact factor: 2.155

5.  Impact of deformation on a supine-positioned image-guided breast surgery approach.

Authors:  Winona L Richey; Jon S Heiselman; Ma Luo; Ingrid M Meszoely; Michael I Miga
Journal:  Int J Comput Assist Radiol Surg       Date:  2021-08-12       Impact factor: 3.421

6.  Accurate resection of nonpalpable, ultrasonography undetectable breast cancer tumor by preoperative indocyanine green injection using stereotactic mammography: A case report.

Authors:  Atsushi Muraoka; Masahiko Kobayashi
Journal:  Ann Med Surg (Lond)       Date:  2022-06-07

Review 7.  Intraoperative ultrasound guidance is associated with clear lumpectomy margins for breast cancer: a systematic review and meta-analysis.

Authors:  Hong Pan; Naping Wu; Hao Ding; Qiang Ding; Juncheng Dai; Lijun Ling; Lin Chen; Xiaoming Zha; Xiaoan Liu; Wenbin Zhou; Shui Wang
Journal:  PLoS One       Date:  2013-09-20       Impact factor: 3.240

8.  Optimization of breast cancer excision by intraoperative ultrasound and marking needle - technique description and feasibility.

Authors:  Nebojsa S Ivanovic; Darko D Zdravkovic; Zlatko Skuric; Jelena Kostic; Natasa Colakovic; Miodrag Stojiljkovic; Svetlana Opric; Magdalena Stefanovic Radovic; Ivan Soldatovic; Biljana Sredic; Miroslav Granic
Journal:  World J Surg Oncol       Date:  2015-04-18       Impact factor: 2.754

9.  Toolbox to Reduce Lumpectomy Reoperations and Improve Cosmetic Outcome in Breast Cancer Patients: The American Society of Breast Surgeons Consensus Conference.

Authors:  Jeffrey Landercasper; Deanna Attai; Dunya Atisha; Peter Beitsch; Linda Bosserman; Judy Boughey; Jodi Carter; Stephen Edge; Sheldon Feldman; Joshua Froman; Caprice Greenberg; Cary Kaufman; Monica Morrow; Barbara Pockaj; Melvin Silverstein; Lawrence Solin; Alicia Staley; Frank Vicini; Lee Wilke; Wei Yang; Hiram Cody
Journal:  Ann Surg Oncol       Date:  2015-07-28       Impact factor: 5.344

10.  Intraoperative ultrasound reduces the need for re-excision in breast-conserving surgery.

Authors:  Hasan Karanlik; Ilker Ozgur; Dilek Sahin; Merdan Fayda; Semen Onder; Ekrem Yavuz
Journal:  World J Surg Oncol       Date:  2015-11-24       Impact factor: 2.754

View more