Literature DB >> 22866288

Immediate versus early loading of 6.5 mm-long flapless-placed single implants: a 4-year after loading report of a split-mouth randomised controlled trial.

Gioacchino Cannizzaro1, Pietro Felice, Michele Leone, Vittorio Ferri, Paolo Viola, Marco Esposito.   

Abstract

PURPOSE: To evaluate the medium-term effectiveness of 6.5 mm-long flapless-placed single implants immediately or early loaded at 6 weeks.
MATERIALS AND METHODS: Thirty patients received two single NanoTite external hex Biomet 3i implants each, which were then randomly allocated to be immediately or early loaded according to a splitmouth design. Implants had to be inserted with a minimum torque of >40 Ncm. Provisional crowns were put in slight occlusal contact and replaced by definitive crowns 3 months after loading. Patients were followed for 4 years after loading. Outcome measures were implant failures, biological and biomechanical complications, peri-implant marginal bone level changes, and patient preference.
RESULTS: Twenty-nine implants were immediately loaded and 31 early loaded. Four years after loading, no drop-outs occurred. One implant failed in each group within 2 months after loading. Seven patients experienced complications at immediately loaded implants and 6 at early loaded implants. There were no statistically significant differences between groups for implant losses, complications, mean marginal bone level changes and patient preference.
CONCLUSIONS: Flapless-placed 6.5 mm-long single implants can be immediately loaded and remain successful up to 4 years after loading. Even longer follow-ups are still needed to evaluate the longterm prognosis of short implants.

Entities:  

Mesh:

Year:  2012        PMID: 22866288

Source DB:  PubMed          Journal:  Eur J Oral Implantol        ISSN: 1756-2406            Impact factor:   3.123


  7 in total

Review 1.  Interventions for replacing missing teeth: different times for loading dental implants.

Authors:  Marco Esposito; Maria Gabriella Grusovin; Hassan Maghaireh; Helen V Worthington
Journal:  Cochrane Database Syst Rev       Date:  2013-03-28

2.  Success and patient satisfaction of immediately loaded zirconia implants with fixed restorations one year after loading.

Authors:  Rico Rutkowski; Ralf Smeets; Leon Neuhöffer; Carolin Stolzer; Kilian Strick; Martin Gosau; Susanne Sehner; Karl Ulrich Volz; Anders Henningsen
Journal:  BMC Oral Health       Date:  2022-05-23       Impact factor: 3.747

3.  Survival of immediately versus delayed loaded short implants: A prospective case series study.

Authors:  Joaquin Alvira-González; Erick Díaz-Campos; Maria-Angeles Sánchez-Garcés; Cosme Gay-Escoda
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2015-07-01

4.  Immediate Loading of Short Implants in Posterior Maxillae: Case Series.

Authors:  Eduardo Anitua
Journal:  Acta Stomatol Croat       Date:  2017-06

5.  Immediate functional loading of single implants: a multicenter study with 4 years of follow-up.

Authors:  Filiep Raes; Tammaro Eccellente; Carolina Lenzi; Michele Ortolani; Giuseppe Luongo; Carlo Mangano; Francesco Mangano
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2018-03-14

6.  Immediate loading of short implants: A systematic review.

Authors:  Mahdi Hadilou; Pooya Ebrahimi; Behnaz Karimzadeh; Ashkan Ghaffary; Leila Gholami; Zahra Fathifar
Journal:  J Adv Periodontol Implant Dent       Date:  2021-03-06

Review 7.  Dental Implants Inserted in Fresh Extraction Sockets versus Healed Sites: A Systematic Review and Meta-Analysis.

Authors:  Adam Ibrahim; Bruno Ramos Chrcanovic
Journal:  Materials (Basel)       Date:  2021-12-20       Impact factor: 3.623

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.